Testing of a Noninvasive Probe for Measurement of Blood Perfusion
Authors:
- 1 March 2008
- journal article
- Published by ASME International in Journal of Medical Devices
- Vol. 2 (1) , 011001
Abstract
Parameter estimation techniques have been utilized in the development of a methodology to noninvasively measure blood perfusion using a new thermal surface probe. The core of this probe is comprised of a small, lightweight heat flux sensor that is placed in contact with tissue and provides time-resolved signals of heat flux and surface temperature while the probe is cooled by air jets. Parameter estimation techniques were developed that incorporate heat flux and temperature data with calculated data from a biothermal model of the tissue and probe. The technique simultaneously estimates blood perfusion and thermal contact resistance between the probe and tissue. Validation of this concept was carried out by experimentation with controlled flow through nonbiological porous media. Warm water was circulated through a fine pore sponge to provide a phantom model for blood perfusion through biological tissue. The parameter estimation technique was applied to measurements taken over a range of flow rates. Heat flux and temperature measurements and the resulting perfusion estimates correlated well with the experimentally imposed perfusion rate. This research helps establish the validity of using this method to develop a practical, noninvasive probe to clinically measure blood perfusion.Keywords
This publication has 17 references indexed in Scilit:
- Comparative Overview of Brain Perfusion Imaging TechniquesStroke, 2005
- A comparison of two laser-based methods for determination of burn scar perfusion: Laser Doppler versus laser speckle imagingBurns, 2005
- Thermal Diffusion Probe Analysis of Perfusion Changes in Vascular Occlusions of Rabbit Pedicle FlapsPlastic and Reconstructive Surgery, 2005
- Stray field magnetic resonance imaging: a preliminary study of skin hydrationJournal of Physics D: Applied Physics, 2003
- Local perfusion and metabolic demand during exercise: a noninvasive MRI method of assessmentJournal of Applied Physiology, 2001
- Continuous monitoring of regional cerebral blood flow: experimental and clinical validation of a novel thermal diffusion microprobeJournal of Neurosurgery, 2000
- Laser-Doppler Blood Flowmetry1990
- A Self-Heated Thermistor Technique to Measure Effective Thermal Properties From the Tissue SurfaceJournal of Biomechanical Engineering, 1987
- A Comparative Analysis of Thermal Blood Perfusion Measurement TechniquesJournal of Biomechanical Engineering, 1987
- THERMAL DILUTION METHODS: ESTIMATION OF TISSUE BLOOD FLOW AND METABOLISMAnnals of the New York Academy of Sciences, 1980