Abstract
The emergent FLASH RadioTherapy (RT) uses ultrahigh dose-rate irradiation (up to 107 Gy/s instantaneous dose-rate in each μs pulse) to deliver a single high dose of irradiation in a very short time (in vivo validations, this could represent a breakthrough in cancer treatment. However, the reliability and the accuracy of experimental studies are nowadays limited by the lack of detectors able to measure online the beam fluence at FLASH dose-rates. The behavior of standard beam monitors (gas-filled ionization chambers) is compromised by the volume recombination caused by the amount of charges created per unit volume and unit time, due to the large dose-rate. Moreover, due to the lack of proper monitoring devices and to the uncertainties of its future applications, very few facilities are able to deliver at present FLASH irradiations. In this contribution, we report about the physical and technological challenges of monitoring high and ultra-high dose-rates with electrons and photon beams, starting from the pre-clinical and clinical constraints for new devices. Based on the extensive experience in silicon detectors for monitoring applications in RT with external beams, the work then investigates silicon sensors as a possible option to tackle such extreme requirements and a rugged thin and large (e.g., 10 × 10 cm2) flat detector (silicon-based sensor + readout electronics) is therefore outlined. This study aims at presenting the FLASH-RT dosimetry problem and analyzing the possibilities for a silicon sensor to be employed as sensing device for several FLASH scenarios, including some ideas on the readout part. However, more detailed simulations and studies are demanded to delineate more precisely the technical choices to be undertaken in order to tackle the clinical accuracy required on the beam fluence, typically a few %, during photon and electron high and ultra-high irradiations, the required minimal perturbation of the beam and the high level of radiation resistance.Keywords
This publication has 20 references indexed in Scilit:
- Technology‐driven research for radiotherapy innovationMolecular Oncology, 2020
- FLASH radiotherapy International WorkshopRadiotherapy and Oncology, 2019
- Treatment of a first patient with FLASH-radiotherapyRadiotherapy and Oncology, 2019
- Biological Benefits of Ultra-high Dose Rate FLASH Radiotherapy: Sleeping Beauty AwokenClinical Oncology, 2019
- Dose detectors, sensors, and their applicationsMedical Physics, 2018
- High dose‐per‐pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical useMedical Physics, 2017
- Linear Accelerators for Radiation Therapy2017
- Novel Silicon Devices for Radiation Therapy MonitoringNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in miceScience Translational Medicine, 2014
- Handbook of Radiotherapy Physics2007