Gradient coil and radiofrequency induced heating of orthopaedic implants in MRI: influencing factors
Open Access
- 21 December 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (24) , 245024
Abstract
Patients with implanted orthopaedic devices represent a growing number of subjects undergoing magnetic resonance imaging (MRI) scans each year. MRI safety labelling is required for all implants under the EU Medical Device Regulations to ensure regulatory compliance, with each device assessed through standardised testing procedures. In this paper, we employ parametric studies to assess a range of clinically relevant factors that cause tissue heating, performing simulations with both radiofrequency (RF) and gradient coil (GC) switching fields, the latter of which is often overlooked in the literature. A series of ‘worst-case’ scenarios for both types of excitation field is discussed. In the case of GC fields, large volume implants and large plate areas with the field orientated perpendicular to the plane cause the highest heating levels, along with sequences with high rates of field switching. Implant heating from RF fields is driven primarily from the ‘antenna effect’, with thin, linear implants of resonant length resulting in the highest temperature rises. In this work, we show that simplifications may be made to the field sequence and in some cases the device geometry without significantly compromising the accuracy of the simulation results, enabling the possibility for generic estimates of the implant heating for orthopaedic device manufacturers and opportunities to simplify the safety compliance process.Keywords
Funding Information
- Horizon 2020 Framework Programme (17IND01)
This publication has 34 references indexed in Scilit:
- A GPU Computational Code for Eddy-Current Problems in Voxel-Based AnatomyIEEE Transactions on Magnetics, 2015
- Numerical prediction of temperature elevation induced around metallic hip prostheses by traditional, split, and uniplanar gradient coilsMagnetic Resonance in Medicine, 2015
- Computational and experimental studies of an orthopedic implant: MRI‐related heating at 1.5‐T/64‐MHz and 3‐T/128‐MHzJournal of Magnetic Resonance Imaging, 2012
- Numerical simulation of SAR induced around Co‐Cr‐Mo hip prostheses in situ exposed to RF fields associated with 1.5 and 3 T MRI body coilsMagnetic Resonance in Medicine, 2011
- Resolution adapted finite element modeling of radio frequency interactions on conductive resonant structures in MRIMagnetic Resonance in Medicine, 2011
- Effect of RF pulse sequence on temperature elevation for a given time‐average SARConcepts in Magnetic Resonance Part B, 2010
- A Numerical Investigation of RF Heating Effects on Implants During MRI Compared to Experimental MeasurementsSpringer Proceedings in Physics, 2007
- Testing methods for MR safety and compatibility of medical devicesMinimally Invasive Therapy & Allied Technologies, 2006
- A fast and accurate simulator for the design of birdcage coils in MRIMagnetic Resonance Materials in Physics, Biology and Medicine, 2002
- PROCEEDINGS OF THE PHYSIOLOGICAL SOCIETY: January 22, 1910The Journal of Physiology, 1910