Orientation-Independent Catheter-Based Characterization of Myocardial Activation
Authors:
Open Access
- 7 July 2016
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (5) , 1067-1077
Abstract
Cardiac electrogram (EGM) signals and electrophysiologic (EP) characteristics derived from them such as amplitude and timing are central to the diagnosis and therapeutic management of arrhythmias. Bipolar EGMs are often used but possess polarity and shape dependence on catheter orientation contributing to uncertainty. Objective: We describe a novel method to map cardiac activation that resolves signals into meaningful directions and is insensitive to electrode directional effects. Methods: Multielectrode catheters that span 2- and 3-D space are used to derive local electric field (E-field) signals. A traveling wave model of local EGM propagation motivates a new “omnipolar” reference frame in which to understand EGM E-field signals and provide bipolar component EGMs aligned with these anatomic and physiologic directions. We validate the basis of this technology and determine its accuracy using a saline tank in which we simulate physiologic propagation. Results: Omnipole signals from healthy tissue are nearly free of catheter orientation effects and are constrained by biophysics to consistent morphologies and thus consistent measured amplitudes and timings. Using a 3-D EP mapping system, traveling wave treatment, and omnipolar technology (OT) E-field loops, we derived a new and nearly instantaneous means to determine conduction velocity and activation direction. Conclusion: We describe the basis of OT and validate it with ablation and mapping catheters in a saline tank. Finally, we illustrate OT with signals from live subjects. Significance: OT's novel approach with signal processing and real-time visualization allows for a newly detailed characterization of myocardial activation that is insensitive to catheter orientation.Keywords
Funding Information
- St. Jude Medical
- St. Paul, MN, USA
This publication has 19 references indexed in Scilit:
- The Rotor RevolutionCirculation: Arrhythmia and Electrophysiology, 2014
- Relationship Between Voltage Map “Channels” and the Location of Critical Isthmus Sites in Patients With Post-Infarction Cardiomyopathy and Ventricular TachycardiaJACC, 2013
- Treatment of Atrial Fibrillation by the Ablation of Localized SourcesJACC, 2012
- The Pathophysiologic Basis of Fractionated and Complex Electrograms and the Impact of Recording Techniques on Their Detection and InterpretationCirculation: Arrhythmia and Electrophysiology, 2010
- Velocity Field Analysis of Activation Maps in Atrial Fibrillation A Simulation Study2009
- Identification of Cardiac Rhythm Features by Mathematical Analysis of Vector FieldsIEEE Transactions on Biomedical Engineering, 2004
- Lesion Size Estimator of Cardiac Radiofrequency Ablation at Different Common Locations With Different Tip TemperaturesIEEE Transactions on Biomedical Engineering, 2004
- Estimation of Cardiac Conduction Velocities Using Small Data SetsAnnals of Biomedical Engineering, 2003
- The Effect of Ablation Electrode Length and Catheter Tip to Endocardial Orientation on Radiofrequency Lesion Size in the Canine Right AtriumPacing and Clinical Electrophysiology, 2002
- Estimation of conduction velocity vector fields from epicardial mapping dataIEEE Transactions on Biomedical Engineering, 1998