Abstract
Cardiac arrest is a common cause of death in the world. Immediate high-quality cardiopulmonary resuscitation (CPR) improves the chances of survival of cardiac arrest patients. In particular, maintaining an adequate chest compression depth (CCD) during CPR is a key determinant for survival from cardiac arrest. If it is possible to measure the CCD accurately during CPR, we could increase the survival rate of patients by improving the quality of CPR. This work proposes a new sensor that could measure the CCD accurately during CPR. Compared with existing sensors that utilize pressures or accelerometers, the proposed sensor employs distance measurements based on the time-difference-of-arrival using impulse-radio ultra-wideband (IR-UWB). The method directly measures the CCD using two antennas at the chest and at the back, thereby eliminating the distance error under CPR environments, which is present in existing accelerometer sensors. The designed sensor has an 0.08 mm resolution, and an inaccuracy of less than ±1.25 mm, within a range of 0-40 cm. This sensor was applied to a CPR manikin to measure the CCD in an environment where CPR is performed.Keywords
Funding Information
- National Research Foundation of Korea funded by the Korea government MISP (NRF-2013R1A2A2A05005818)
This publication has 38 references indexed in Scilit:
- The use of dual accelerometers improves measurement of chest compression depthResuscitation, 2012
- New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrestResuscitation, 2010
- Compression feedback devices over estimate chest compression depth when performed on a bedResuscitation, 2009
- Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional studyResuscitation, 2006
- The quality of chest compressions by trained personnel: The effect of feedback, via the CPREzy, in a randomized controlled trial using a manikin modelResuscitation, 2006
- A CMOS Ultra-Wideband Impulse Radio Transceiver for 1-Mb/s Data Communications and$pm$2.5-cm Range FindingIEEE Journal of Solid-State Circuits, 2006
- Pulse detection algorithm for line-of-sight (LOS) UWB ranging applicationsIEEE Antennas and Wireless Propagation Letters, 2005
- CPREzy™: an evaluation during simulated cardiac arrest on a hospital bedResuscitation, 2005
- Microwave imaging via space-time beamforming for early detection of breast cancerIEEE Transactions on Antennas and Propagation, 2003
- UWB radars in medicineIEEE Aerospace and Electronic Systems Magazine, 2002