Temperature Study of CdZnTe Coplanar-Grid Detectors
Authors:
- 16 October 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (5) , 3035-3040
Abstract
The coplanar-grid (CPG) and other electron-only detection techniques have made possible the use of CdZnTe-based detectors for gamma-ray spectroscopy when high efficiency, good energy resolution, and near room temperature operation are required. Despite the demonstrated potential of the technologies, widespread use remains hampered in part by the limited availability of the highly uniform CdZnTe material required for high-resolution spectroscopy. However, it has been recently shown that mild cooling of CdZnTe CPG detectors can result in a significant improvement in the energy resolution of the detectors thereby allowing a wider range of material to be used for high-resolution applications. In this paper, we show that improved spectroscopic performance can consistently be achieved through a combination of detector cooling and increased detector bias. Energy resolutions of about 1% FWHM at 662 keV for detector volumes up to 2.3 cm3 have been obtained at -20degC. With the electronic noise subtracted, this amounts to an intrinsic resolution of 0.8%. We also show that further cooling of the detectors to -30degC leads to field polarization and a loss of spectroscopic performanceKeywords
This publication has 15 references indexed in Scilit:
- Investigation of the asymmetric characteristics and temperature effects of CdZnTe detectorsIEEE Transactions on Nuclear Science, 2005
- Pocket-size CdZnTe gamma-ray spectrometerIEEE Transactions on Nuclear Science, 2005
- Performance improvement of large volume CdZnTe detectors2005
- Noise in CdZnTe detectorsIEEE Transactions on Nuclear Science, 2001
- A CdZnTe coplanar-grid detector array for environmental remediationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- CdZnTe material uniformity and coplanar-grid gamma-ray detector performanceIEEE Transactions on Nuclear Science, 2000
- Optimization criteria for coplanar-grid detectorsIEEE Transactions on Nuclear Science, 1999
- Position-sensitive single carrier CdZnTe detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- 1-D position sensitive single carrier semiconductor detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Improving CdZnTe X-ray detector performance by cooling and rise time discriminationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996