Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes
Authors:
- Rudy M.M.A. NuijtsRNRudy M.M.A. Nuijts
- Soraya M.R. JonkerSJSoraya M.R. Jonker
- Robert A. KauferRKRobert A. Kaufer
- Ruth Lapid-GortzakRLRuth Lapid-Gortzak
- Javier MendicuteJMJavier Mendicute
- Cristina Peris MartinezCristina Peris Martinez
- Stefanie SchmicklerSSStefanie Schmickler
- Thomas KohnenTKThomas Kohnen
- 1 February 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (2) , 194-202
Abstract
To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm).Keywords
This publication has 11 references indexed in Scilit:
- Bilateral mix-and-match versus unilateral multifocal intraocular lens implantation: Long-term comparisonJournal of Cataract & Refractive Surgery, 2013
- Outcomes of the AcrySof ReSTOR IOL in Myopes, Emmetropes, and HyperopesJournal of Refractive Surgery, 2009
- Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D additionJournal of Cataract & Refractive Surgery, 2009
- Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition powerJournal of Cataract & Refractive Surgery, 2009
- One-Year Outcomes with New-Generation Multifocal Intraocular LensesOphthalmology, 2008
- Prospective visual evaluation of apodized diffractive intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Cataract EpidemiologyOphthalmology, 2007
- Visual Performance of AcrySof ReSTOR Apodized Diffractive IOL: A Prospective Comparative TrialAmerican Journal of Ophthalmology, 2006
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006
- Visual Acuity, Contrast Sensitivity, Reading Speed, and Wavefront Analysis: Pseudophakic Eye With Multifocal IOL (ReSTOR) Versus Fellow Phakic Eye in Non-presbyopic PatientsJournal of Refractive Surgery, 2006