Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
Authors:
Open Access
- 11 February 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (4) , 754-760
Abstract
Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investigated by separation of the heterogeneity correction effects into photon attenuation and electron transport. Under Institutional Review Board exemption status, 74 patients with lung cancer who were treated with SBRT were retrospectively evaluated. All treatment plans were generated using an anisotropic analytical algorithm (AAA) of an Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system. Two additional plans were created using the same treatment parameters (monitor units, beam angles and energy): a plan with no heterogeneity correction (NC), and a plan calculated with a pencil beam convolution algorithm (PBC). Compared with NC, AAA and PBC isocenter doses were on average 13.4% and 21.8% higher, respectively. The differences in the isocenter dose and the dose coverage for 95% of the PTV (D95%) between PBC and AAA were correlated logarithmically (ρ = 0.78 and ρ = 0.46, respectively) with PTV. Although D95% calculated with AAA was in general 2.9% larger than that for NC, patients with a small PTV showed a negative ΔD95% for AAA due to the significant effect of electron transport. The PTV volume shows logarithmic correlation with the effects of the lateral electron transport. These findings indicate that the dosimetric metrics and prescription, especially in clinical trials, should be clearly evaluated in the context of target volume characteristics and with proper heterogeneity correction.Keywords
This publication has 25 references indexed in Scilit:
- Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-Corrected Conformal Treatment Plans Following RTOG 0813 Dosimetric Criteria for Lung Cancer Stereotactic Body RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculationsMedical Physics, 2011
- Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung CancerJAMA, 2010
- The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverageRadiotherapy and Oncology, 2009
- Small fields: Nonequilibrium radiation dosimetryMedical Physics, 2007
- Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planningRadiotherapy and Oncology, 2006
- Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403)Physics in Medicine & Biology, 2006
- Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computationsMedical Physics, 2006
- Stereotactic hypofractionated high‐dose irradiation for stage I nonsmall cell lung carcinomaCancer, 2004
- Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaMedical Physics, 1989