An Experimental Investigation of the Convective Heat Transfer on a Small Helicopter Rotor with Anti-Icing and De-Icing Test Setups
Open Access
Abstract
Successful icing/de-icing simulations for rotorcraft require a good prediction of the convective heat transfer on the blade’s surface. Rotorcraft icing is an unwanted phenomenon that is known to cause flight cancelations, loss of rotor performance and severe vibrations that may have disastrous and deadly consequences. Following a series of experiments carried out at the Anti-icing Materials International Laboratory (AMIL), this paper provides heat transfer measurements on heated rotor blades, under both the anti-icing and de-icing modes in terms of the Nusselt Number (Nu). The objective is to develop correlations for the Nu in the presence of (1) an ice layer on the blades (NuIce) and (2) liquid water content (LWC) in the freestream with no ice (NuWet). For the sake of comparison, the NuWet and the NuIce are compared to heat transfer values in dry runs (NuDry). Measurements are reported on the nose of the blade-leading edge, for three rotor speeds (Ω) = 500, 900 and 1000 RPM; a pitch angle (θ) = 6°; and three different radial positions (r/R), r/R = 0.6, 0.75 and 0.95. The de-icing tests are performed twice, once for a glaze ice accretion and another time for rime ice. Results indicate that the NuDry and the NuWet directly increased with V∝, r/R or Ω, mainly due to an increase in the Reynolds number (Re). Measurements indicate that the NuWet to NuDry ratio was always larger than 1 as a direct result of the water spray addition. NuIce behavior was different and was largely affected by the ice thickness (tice) on the blade. However, the ice acted as insulation on the blade surface and the NuIce to NuDry ratio was always less than 1, thus minimizing the effect of convection. Four correlations are then proposed for the NuDry, the NuWet and the NuIce, with an average error between 3.61% and 12.41%. The NuDry correlation satisfies what is expected from heat transfer near the leading edge of an airfoil, where the NuDry correlates well with Re0.52.Keywords
Funding Information
- Bell (ENV702)
- Consortium de Recherche et d’innovation en Aérospatiale au Québec (ENV702)
- SOCOMORE (ENV702)
- Natural Sciences and Engineering Research Council of Canada (CRD 478088-14)
This publication has 40 references indexed in Scilit:
- Convective Heat Transfer from a NACA Airfoil at Varying Angles of AttackJournal of Thermophysics and Heat Transfer, 2008
- Experimental correlation of forced convection heat transfer from a NACA airfoilExperimental Thermal and Fluid Science, 2007
- Convective Droplet Impact and Heat Transfer from a NACA AirfoilJournal of Thermophysics and Heat Transfer, 2007
- Development of a Second Generation In-Flight Icing Simulation CodeJournal of Fluids Engineering, 2005
- Heat Transfer Coefficient Measurement on Iced Airfoil in Small Icing Wind TunnelJournal of Thermophysics and Heat Transfer, 2000
- Anti-Icing System Simulation Using CANICEJournal of Aircraft, 1999
- Aircraft anti-icing and de-icing techniques and modelingJournal of Aircraft, 1996
- Heat transfer measurements from a smooth NACA 0012 airfoilJournal of Aircraft, 1991
- Describing the uncertainties in experimental resultsExperimental Thermal and Fluid Science, 1988
- Correlation of icing relationships with airfoil and rotorcraft icingdataJournal of Aircraft, 1986