Abstract
Objective: To evaluate the outcome of aortic root augmentation by the Konno-aortoventriculoplasty technique as part of reoperative aortic valve replacement. Methods: Since 1983, 15 patients, 12 males and three females, had repeat aortic valve replacement (AVR) with concomitant Konno aortoventriculoplasty. Age ranged from 1.2 to 18 years (mean 12.5 years). The underlying anatomic diagnoses were valve and subvalvar aortic stenosis in 11, truncal valve insufficiency in one, endocarditis in one, Shone's complex in one and severe aortic insufficiency associated with a ventricular septal defect in one patient. All patients had had previous AVR. The causes for reoperation were prosthetic valve stenosis due to growth in ten and paravalvular leak in one, homograft failure in two, xenograft failure in one, and left ventricular outflow tract obstruction (LVOTO) after mitral valve replacement in one patient. The mean size of explanted prostheses was 19.2 mm (13–23 mm) while the mean size of the implanted prostheses was 24.3 mm (19–27 mm) (P≪0.01). Previous aortic root enlargement had been performed in 11 patients in conjunction with AVR. The Manougian technique was used previously in two, Konno aortoventriculoplasty in eight, and both techniques in one patient. The newly implanted aortic valves were a homograft in one patient and mechanical prostheses in 14 patients. Results: There was one operative death (1 of 15 or 6.6%) in a 17.5 year old patient with previous AVR and posterior root enlargement, due to low cardiac output state. Follow-up ranged from 6 months to 17 years (mean 7.2 years). The only late death occurred in an 11.6-year-old patient due to prosthetic valve endocarditis. Two patients had complete heart block and had permanent pacemaker insertion (2 of 15 or 13.3%). One patient had pulmonary valve replacement because of combined stenosis and insufficiency 5 years after operation. All 13-surviving patients are asymptomatic at latest follow up. Conclusion: Konno aortoventriculoplasty with repeat AVR may be safely performed. Excellent results may be achieved despite previous aortic root enlargement. It is a good surgical option for complex LVOTO and may even reduce reoperation in children by allowing placement of a larger prosthesis.Keywords
This publication has 15 references indexed in Scilit:
- Konno-aortoventriculoplasty with mechanical prosthesis in dealing with small aortic root: a good surgical optionEuropean Journal of Cardio-Thoracic Surgery, 1997
- Pulmonary autograft in children: Realized growth potentialThe Annals of Thoracic Surgery, 1994
- Aortic Valve Prosthesis Obstruction After Aortoventriculoplasty: Reconstruction with Aortic AllograftJournal of Cardiac Surgery, 1994
- Medium-term follow-up of pulmonary autograft replacement of aortic valves in childrenEuropean Journal of Cardio-Thoracic Surgery, 1994
- Pulmonary Autograft Aortic Valve Replacement: Long-Term ResultsJournal of Cardiac Surgery, 1991
- Extended aortic root replacement with cryopreserved allografts: Do they hold up?The Annals of Thoracic Surgery, 1991
- Prosthetic valves in children and adolescentsAmerican Heart Journal, 1991
- Aortic Valve Replacement with Concomitant Aortoventriculoplasty in Children and Young Adults: Long-term Follow-upThe Annals of Thoracic Surgery, 1987
- Patch enlargement of the aortic valve ring by extending the aortic incision into the anterior mitral leafletThe Journal of Thoracic and Cardiovascular Surgery, 1979
- Hypoplasia of the aortic root : The problem of aortic valve replacementThorax, 1970