Heavy Metal Ions Inhibition of Jack Bean Urease: Potential for Rapid Contaminant Probing
Open Access
- 1 February 2004
- journal article
- research article
- Published by Taylor & Francis in Journal of Enzyme Inhibition and Medicinal Chemistry
- Vol. 19 (1) , 65-69
Abstract
The kinetics of heavy metal ions inhibition of jack bean urease was studied by progress curve analysis in a reaction system without enzyme-inhibitor preincubation. The inhibition was found to be biphasic with an initial, small inhibitory phase changing over the time course of 5–10 min into a final linear steady state with a lower velocity. This time-dependent pattern was best described by mechanism B of slow-binding inhibition, involving the rapid formation of an EI complex that subsequently undergoes slow conversion to a more stable EI* complex. The kinetic parameters of the process, the inhibition constants Ki and Ki* and the forward k5 and reverse k6 rate constants for the conversion, were evaluated from the reaction progress curves by nonlinear regression treatment. Based on the values of the overall inhibition constant Ki*, the heavy metal ions were found to inhibit urease in the following decreasing order: Hg2+ > Cu2+ > Zn2+ > Cd2+ > Ni2+ > Pb2+ > Co2+ > Fe3+ > As3+. With the Ki* values as low as 1.9 nM for Hg2+ and 7.1 nM for Cu2+, 100–1000 times lower than those of the other ions, urease may be utilized as a bioindicator of the trace levels of these ions in environmental monitoring, bioprocess control or pharmaceutical analysis.Keywords
This publication has 16 references indexed in Scilit:
- Simple optical fibre biosensor based on immobilised enzyme for monitoring of trace heavy metal ionsAnalytical and Bioanalytical Chemistry, 2003
- Sol–gel derived urease-based optical biosensor for the rapid determination of heavy metalsAnalytica Chimica Acta, 2003
- Enzyme inhibition-based biosensors and biosensing systems: questionable analytical devicesBiosensors and Bioelectronics, 2002
- Environmental toxicity monitoring using electrochemical biosensing systems.Environmental Science and Pollution Research, 2001
- Inhibitive determination of mercury and other metal ions by potentiometric urea biosensorBiosensors and Bioelectronics, 2001
- Multienzyme electrochemical sensor array for determination of heavy metal ionsSensors and Actuators B: Chemical, 1999
- Disposable cuvette test with integrated sensor layer for enzymatic determination of heavy metalsBiosensors and Bioelectronics, 1996
- Application of urease conductometric biosensor for heavy-metal ion determinationSensors and Actuators B: Chemical, 1995
- Effect of the coupling reagent on the metal inhibition of immobilized urease in an optical biosensorThe Analyst, 1995
- The Inhibition of Urease by Metal Ions at pH 8.9Journal of the American Chemical Society, 1961