Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss
Open Access
- 20 May 2013
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 45
Abstract
Background: Zirconia materials are known for their optimal aesthetics, but they are brittle, and concerns remain about whether their mechanical properties are sufficient for withstanding the forces exerted in the oral cavity. Therefore, this study compared the maximum deformation and failure forces of titanium implants between titanium-alloy and zirconia abutments under oblique compressive forces in the presence of two levels of marginal bone loss. Methods: Twenty implants were divided into Groups A and B, with simulated bone losses of 3.0 and 1.5 mm, respectively. Groups A and B were also each divided into two subgroups with five implants each: (1) titanium implants connected to titanium-alloy abutments and (2) titanium implants connected to zirconia abutments. The maximum deformation and failure forces of each sample was determined using a universal testing machine. The data were analyzed using the nonparametric Mann–Whitney test. Results: The mean maximum deformation and failure forces obtained the subgroups were as follows: A1 (simulated bone loss of 3.0 mm, titanium-alloy abutment) = 540.6 N and 656.9 N, respectively; A2 (simulated bone loss of 3.0 mm, zirconia abutment) = 531.8 N and 852.7 N; B1 (simulated bone loss of 1.5 mm, titanium-alloy abutment) = 1070.9 N and 1260.2 N; and B2 (simulated bone loss of 1.5 mm, zirconia abutment) = 907.3 N and 1182.8 N. The maximum deformation force differed significantly between Groups B1 and B2 but not between Groups A1 and A2. The failure force did not differ between Groups A1 and A2 or between Groups B1 and B2. The maximum deformation and failure forces differed significantly between Groups A1 and B1 and between Groups A2 and B2. Conclusions: Based on this experimental study, the maximum deformation and failure forces are lower for implants with a marginal bone loss of 3.0 mm than of 1.5 mm. Zirconia abutments can withstand physiological occlusal forces applied in the anterior region.Keywords
This publication has 34 references indexed in Scilit:
- Systematic review of the survival rate and the biological, technical, and aesthetic complications of fixed dental prostheses with cantilevers on implants reported in longitudinal studies with a mean of 5 years follow‐upClinical Oral Implants Research, 2012
- Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prosthesesClinical Oral Investigations, 2011
- Initial stability and bone strain evaluation of the immediately loaded dental implant: an in vitro model studyClinical Oral Implants Research, 2010
- Current challenges in successful rehabilitation with oral implantsJournal of Oral Rehabilitation, 2010
- Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracyClinical Oral Investigations, 2010
- Relationship between Sponsorship and Failure Rate of Dental Implants: A Systematic ApproachPLOS ONE, 2010
- Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crownsClinical Oral Investigations, 2010
- The influence of gender and bruxism on human minimum interdental threshold abilityJournal of Applied Oral Science, 2009
- Radiographic Analyses of “Advanced” Marginal Bone Loss Around Brånemark® Dental ImplantsClinical Implant Dentistry and Related Research, 2009
- Esthetic High‐Strength Implant Abutments. Part IIJournal of Esthetic and Restorative Dentistry, 1993