Sutureless Lamellar Keratoplasty
Authors:
- Terry KimTKTerry Kim
- 1 October 2007
- journal article
- case report
- Published by Wolters Kluwer Health in Cornea
- Vol. 26 (9) , 1127-1128
Abstract
To report a case where fibrin glue was applied with a modified approach to secure the graft to the host bed in lamellar keratoplasty. One patient with epithelial membrane dystrophy, Salzmann nodular degeneration, and amyloid deposits in the cornea underwent lamellar keratoplasty by using fibrin glue. The glue components were applied separately: the fibrin component on the stromal bed and thrombin component on the stromal side of the lamellar graft. Tissue adhesion, corneal condition, and visual acuity were evaluated postoperatively. Best-corrected visual acuity 4 months after surgery was 20/30. The graft remained clear and well positioned 9 months after surgery. We report a case of visual acuity improvement and efficient adhesion of the lamellar graft after lamellar keratoplasty by using fibrin adhesive. The components of the glue can be applied separately, allowing more time to position the graft on the stromal bed.Keywords
This publication has 4 references indexed in Scilit:
- Human fibrin tissue adhesive for sutureless lamellar keratoplasty and scleral patch adhesionOphthalmology, 2003
- Human Fibrin Tissue Glue for Corneal Lamellar Adhesion in RabbitsCornea, 2003
- Indications and Outcome of Optical Partial Thickness Lamellar KeratoplastyCornea, 2003