Optimization of b‐value sampling for diffusion‐weighted imaging of the kidney
Open Access
- 23 June 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (1) , 89-97
Abstract
Diffusion‐weighted imaging (DWI) involves data acquisitions at multiple b values. In this paper, we presented a method of selecting the b values that maximize estimation precision of the biexponential analysis of renal DWI data. We developed an error propagation factor for the biexponential model, and proposed to optimize the b‐value samplings by minimizing the error propagation factor. A prospective study of four healthy human subjects (eight kidneys) was done to verify the feasibility of the proposed protocol and to assess the validity of predicted precision for DWI measures, followed by Monte Carlo simulations of DWI signals based on acquired data from renal lesions of 16 subjects. In healthy subjects, the proposed methods improved precision (P = 0.003) and accuracy (P < 0.001) significantly in region‐of‐interest based biexponential analysis. In Monte Carlo simulation of renal lesions, the b‐sampling optimization lowered estimation error by at least 20–30% compared with uniformly distributed b values, and improved the differentiation between malignant and benign lesions significantly. In conclusion, the proposed method has the potential of maximizing the precision and accuracy of the biexponential analysis of renal DWI. Magn Reson Med, 2011.Keywords
This publication has 35 references indexed in Scilit:
- Statistical evaluation of diffusion‐weighted imaging of the human kidneyMagnetic Resonance in Medicine, 2010
- Variability of Renal Apparent Diffusion Coefficients: Limitations of the Monoexponential Model for Diffusion QuantificationRadiology, 2010
- Usefulness of Diffusion-Weighted Imaging in the Evaluation of Renal MassesAmerican Journal of Roentgenology, 2010
- Application of 3D‐MR image registration to monitor diseases around the knee jointJournal of Magnetic Resonance Imaging, 2005
- Diffusion-weighted MRI in the evaluation of renal lesions: preliminary resultsBritish Journal of Radiology, 2004
- Selection of the optimum b factor for diffusion‐weighted magnetic resonance imaging assessment of ischemic strokeMagnetic Resonance in Medicine, 2004
- Biexponential diffusion tensor analysis of human brain diffusion dataMagnetic Resonance in Medicine, 2004
- Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brainMagnetic Resonance Imaging, 1997
- A power primer.Psychological Bulletin, 1992
- The quantitative limitations of exponential curve fittingPhysics in Medicine & Biology, 1971