A New Wearable System for Postural Balance Assessment: Comparison with EquiTest and Static Posturography in Healthy Adults
Authors:
- Valerio Maria Di Pasquale FiascaVFValerio Maria Di Pasquale Fiasca
- Alfredo Gabriele NanniANAlfredo Gabriele Nanni
- Marco PozziMPMarco Pozzi
- Lorenzo CollinoLCLorenzo Collino
- Barbara MartinoBMBarbara Martino
- Paolo RanieriPRPaolo Ranieri
- Eliana FilipponiEFEliana Filipponi
- Giulio DeheshGDGiulio Dehesh
- Federica Di BerardinoFBFederica Di Berardino
Open Access
- 17 March 2026
- journal article
- research article
- Published by MDPI AG in Audiology Research
- Vol. 16 (2) , 45
Abstract
Background: Objective assessment of postural control is central to the clinical evaluation of vestibular disorders. Although force-platform-based posturography is considered the gold standard, its use may be limited by cost and infrastructural requirements. Wearable inertial measurement units (IMUs) represent a promising alternative; however, their clinical validation should account for intrinsic differences in measurement paradigms rather than strict metric equivalence. Objective: To preliminarily evaluate the within-session reliability of a wearable IMU-based medical device for balance assessment (Gravity), and its agreement with established static (SBP) and computerised dynamic posturographic systems (CDP) in healthy subjects. Methods: Sixty-three healthy adults were enrolled in two independent method comparison studies: a wearable IMU-based balance system versus a static stabilometric platform (GRAVITY vs. SVEP; n = 42) and a wearable IMU-based balance system versus computerised dynamic posturography (Gravity vs. EquiTest; n = 21). Gravity measurements were obtained simultaneously with reference systems across standardised sensory conditions. Within-session reliability and method agreement were assessed. Results: Within-session reliability of Gravity was outcome-dependent. Length-based components demonstrated higher repeatability (ICC (single) = 0.25–0.35; ICC (average) = 0.41–0.52), with narrower limits of agreement (LoA = ±9–12%) and lower measurement error (SEM = 3.3–4.3%). In comparison with SBP, length-based measures exhibited narrower limits (LoA = ±12–17) and more consistent relationships. Comparison with CDP revealed moderate agreement for composite and preferential scores (LoA: −2.20–7.07; −5.54–8.12). Conclusions: Gravity sensor may represent a clinically meaningful, outcome-dependent performance, with superior reliability and comparability for length-based postural measures compared with area-based measures. The device could provide balance assessments compatible with both static and dynamic posturographic systems, accounting for physiological variability. These findings support the potential clinical use of wearable IMU-based posturography, particularly in settings where conventional force-platform systems are not readily available, and warrant further validation in larger, more clinically diverse populations.Keywords
This publication has 32 references indexed in Scilit:
- Reliability of IMU-based balance assessment in clinical stroke rehabilitationGait & Posture, 2022
- Wearable inertial sensors to measure gait and posture characteristic differences in older adult fallers and non-fallers: A scoping reviewGait & Posture, 2020
- Wireless inertial measurement unit (IMU)-based posturographyEuropean Archives of Oto-Rhino-Laryngology, 2019
- Body-worn sensors-the brave new world of clinical measurement?Movement Disorders, 2015
- The use of rubber foam pads and “sensory ratios” to reduce variability in static posturography assessmentGait & Posture, 2009
- Age-related changes of visual contribution in posture controlGait & Posture, 2008
- Age associated differences in postural equilibrium control: A comparison between EQscore and minimum time to contact (TTCmin)Gait & Posture, 2007
- Static and Dynamic Posturography in Patients With Vestibular and Cerebellar LesionsArchives of Neurology, 1998
- Human balance and posture control during standing and walkingGait & Posture, 1995
- Specifications for building a vertical force platform designed for clinical stabilometryMedical & Biological Engineering & Computing, 1985