In vivo Variability in Quantitative Coronary Ultrasound and Tissue Characterization Measurements with Mechanical and Phased-array Catheters
Open Access
- 14 December 2005
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 22 (1) , 47-53
Abstract
Background: Both mechanical and phased-array catheters are used in clinical trials to assess quantitative parameters. Only limited evaluation of the in vivo agreement of volumetrical measurements between such systems has been performed, despite the fact that such information is essential for the conduction of atherosclerosis regression trials. Methods and results: We prospectively evaluated the agreement in morphometric measurements and intravascular ultrasound (IVUS)-based plaque characterization between a 40 MHz rotating transducer (3.2 F Atlantis, Boston Scientific Corp.) and a 20 MHz phased-array catheter (2.9 F Eagle Eye, Volcano Therapeutics, Rancho Cordova, California) in 16 patients. Lumen (7.3 ± 2.0 mm2 vs. 6.7 ± 1.8 mm2, p = 0.001) and vessel (11.8 ± 3.3 mm2 vs. 11.0 ± 2.9 mm2, p = 0.02) cross-sectional areas (CSA) were significantly greater with the 20 MHz system. Plaque CSA measurements showed no significant difference between systems (4.4 ± 2.3 mm2 vs. 4.4 ± 2.1). The relative differences were less than 10% for the three variables. On IVUS-based tissue characterization (13 patients), calculated percentage hypoechogenic volume was significantly higher for the 20 MHz system (96.7 ± 2.38 vs. 88.4 ± 5.53, p < 0.0001). Conclusions: Quantitative IVUS analyses display significant catheter type-dependent variability. It is unclear whether the variability reflects overestimation of measurements with the phased-array or underestimation with the mechanical system. Although plaque burden measurements did not differ significantly between systems, it appears prudent to recommend the use of a single system for progression/regression studies.Keywords
This publication has 20 references indexed in Scilit:
- Regression of Coronary Atherosclerosis by SimvastatinCirculation, 2004
- Variability in quantitative measurement of the same segment with two different intravascular ultrasound systems: In vivo and in vitro studiesCatheterization and Cardiovascular Interventions, 2004
- Spectrum of remodeling behavior observed with serial Long-Term (≥12 months) Follow-Up intravascular ultrasound studies in left main coronary arteriesThe American Journal of Cardiology, 2004
- Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data AnalysisCirculation, 2002
- Atherosclerotic Plaque Characterization by Quantitative Analysis Using Intravascular UltrasoundCirculation Journal, 2002
- Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteriesHeart, 2001
- Intracoronary ultrasound—defined plaque composition: Computer-aided plaque characterization and correlation with histologic samples obtained during directional coronary atherectomyAmerican Heart Journal, 1995
- Intracoronary ultrasound imaging: Intraobserver and interobserver variability of morphometric measurementsAmerican Heart Journal, 1994
- Intravascular ultrasound imaging: In vitro validation and pathologic correlationJACC, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986