Cardiopulmonary effects of internal cardioverter/defibrillator implantation

Authors:

Abstract
Cardiopulmonary effects of electrophysiological testing of internal cardioverter/defibrillator (ICD) devices were studied in ten patients undergoing general anaesthesia. In the control‐phase, haemodynamic performance and oxygenation were slightly impaired. After completion of the electrophysiological procedures (ICD‐phase), cardiopulmonary function had deteriorated significantly. Cardiac index declined by 16%, whereas left ventricular filling pressure and pulmonary vascular resistance increased (P≤0.01). Oxygenation, but not CO2‐elimination deteriorated (P≤0.01) and venous admixture increased by 72% (P≤0.01). Alveolo‐arterial Po2‐difference (PA‐aO2) increased by 43% (P≤0.01), indicating ventilation‐perfusion (VA/Q) mismatching. Repeated inductions of ventricular tachycardia and/or fibrillation subject the myocardium to transient global ischaemia, leading to acute congestive heart failure, and positive inotropic intervention was necessary in 40% of the patients. Partial pulmonary insufficiency resulted possibly from interstitial oedema and VA/Q‐inhomogeneities. ICD implantation has detrimental effects on haemodynamics and gas exchange in patients with impaired left ventricular function.

This publication has 20 references indexed in Scilit: