Patient‐specific finite element modeling of respiratory lung motion using 4D CT image data
Authors:
- René WernerRWRené Werner
- Jan EhrhardtJEJan Ehrhardt
- Rainer SchmidtRSRainer Schmidt
- Heinz HandelsHHHeinz Handels
- 7 April 2009
- journal article
- Published by Wiley in Medical Physics
- Vol. 36 (5) , 1500-1511
Abstract
Development and optimization of methods for adequately accounting for respiratory motion in radiation therapy of thoracic tumors require detailed knowledge of respiratory dynamics and its impact on corresponding dose distributions. Thus, computer aided modeling and simulation of respiratory motion have become increasingly important. In this article a biophysical approach for modeling respiratory lung motion is described: Major aspects of the process of lung ventilation are formulated as a contact problem of elasticity theory which is solved by finite element methods; lung tissue is assumed to be isotropic, homogeneous, and linearly elastic. A main focus of the article is to assess the impact of biomechanical parameters (values of elastic constants) on the modeling process and to evaluate modeling accuracy. Patient‐specific models are generated based on 4D CT data of 12 lung tumor patients. Simulated motion patterns of inner lung landmarks are compared with corresponding motion patterns observed in the 4D CT data. Mean absolute differences between model‐based predicted landmark motion and corresponding breathing‐induced landmark displacements as observed in the CT data sets are in the order of (end expiration to end inspiration) and (end expiration to midrespiration). Modeling accuracy decreases with increasing tumor size both locally (landmarks close to tumor) and globally (landmarks in other parts of the lung). The impact of the values of the elastic constants appears to be small. Outcomes show that the modeling approach is an adequate strategy in predicting lung dynamics due to lung ventilation. Nevertheless, the decreased prediction quality in cases of large tumors demands further study of the influence of lung tumors on global and local lung elasticity properties.Keywords
This publication has 55 references indexed in Scilit:
- Adaptive 4D MR imaging using navigator‐based respiratory signal for MRI‐guided therapyMagnetic Resonance in Medicine, 2008
- Use of three‐dimensional (3D) optical flow method in mapping 3D anatomic structure and tumor contours across four‐dimensional computed tomography dataJournal of Applied Clinical Medical Physics, 2008
- The role of image guidance in respiratory gated radiotherapyActa Oncologica, 2008
- 4D medical image computing and visualization of lung tumor mobility in spatio-temporal CT image dataInternational Journal of Medical Informatics, 2007
- Monitoring of Lung Motion in Patients With Malignant Pleural Mesothelioma Using Two-Dimensional and Three-Dimensional Dynamic Magnetic Resonance ImagingInvestigative Radiology, 2006
- Measurement of tumor diameter-dependent mobility of lung tumors by dynamic MRIRadiotherapy and Oncology, 2004
- Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatmentSeminars in Radiation Oncology, 2004
- Respiration‐correlated spiral CT: A method of measuring respiratory‐induced anatomic motion for radiation treatment planningMedical Physics, 2002
- A modification of Cristy's mathematical human phantoms for Monte Carlo simulationJournal of Radiological Protection, 1992
- Reexamination of the Elastic Properties of Emphysematous LungsRespiration, 1990