High-Field Electrong−2Measurement

Authors:

Abstract
We have measured the g-factor anomaly of the free electron to an accuracy of ± 3 ppm (68% confidence level). The method (a refinement of that used by Wilkinson and Crane in 1963) is based on a direct observation of the difference between the spin precession and cyclotron frequencies of 100-keV electrons confined in a precisely measured magnetic mirror trap. An order of magnitude increase in precision over the Wilkinson-Crane experiment has been achieved by (a) a tenfold increase in the magnitude of the magnetic field (to 1 kG), and (b) a tenfold reduction in the relative depth of the magnetic trap (to 60 ppm). An extensive series of tests for systematic effects at the 1-ppm level has also been carried out. With a=12(g−2), we find aexpt(e−)=(1159657.7±3.5)×10−9. The difference between this result and the current theoretical expression for a, as calculated through second order in the fine-structure constant α, is aexpt(e−)−[0.5(απ)−0.32848(απ)2]=(1.68±0.33)(απ)3. In the above, we have used α−1=137.03608±0.00026, as recently recommended by Taylor, Parker, and Langenberg. The uncertainty in the coefficient is the rms sum of our experimental error and the uncertainty in α−1. In this form, our result can be interpreted as an experimental determination of the sixthorder quantum-electrodynamic contribution to the anomaly. Current estimates of this quantity are 1.49(απ)3.