Stress Assessment of Abutment-Free and Three Implant–Abutment Connections Utilizing Various Abutment Materials: A 3D Finite Element Study of Static and Cyclic Static Loading Conditions
Authors:
- Maryam H. MugriMMMaryam H. Mugri
- Nandalur Kulashekar ReddyNandalur Kulashekar Reddy
- Mohammed E. SayedMohammed E. Sayed
- Khurshid MattooKMKhurshid Mattoo
- Osama Mohammed QomariOQOsama Mohammed Qomari
- Mousa Mahmoud AlnajiMAMousa Mahmoud Alnaji
- Waleed Abdu MshariWMWaleed Abdu Mshari
- Firas K. AlqarawiFiras K. Alqarawi
- Saad Saleh AlResayesSASaad Saleh AlResayes
- Raghdah M. AlshaibaniRARaghdah M. Alshaibani
Open Access
- 2 October 2025
- journal article
- research article
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (10) , 372
Abstract
Background: The implant–abutment interface has been thoroughly examined due to its impact on the success of implant healing and longevity. Removing the abutment is advantageous, but it changes the biomechanics of the implant fixture and restoration. This in vitro three-dimensional finite element analytical (FEA) study aims to evaluate the distribution of von Mises stress (VMS) in abutment-free and three additional implant abutment connections composed of various titanium alloys. Materials and methods: A three-dimensional implant-supported single-crown prosthesis model was digitally generated on the mandibular section using a combination of microcomputed tomography imaging (microCT), a computer-assisted designing (CAD) program (SolidWorks), Analysis of Systems (ANSYS), and a 3D digital scan (Visual Computing Lab). Four digital models [A (BioHorizons), B (Straumann AG), C abutment-free (Matrix), and D (TRI)] representing three different functional biomaterials [wrought Ti-6Al-4Va ELI, Roxolid (85% Ti, 15% Zr), and Ti-6Al-4V ELI] were subjected to simulated static/cyclic static loading in axial/oblique directions after being restored with highly translucent monolithic zirconia restoration. The stresses generated on the implant fixture, abutment, crown, screw, cortical, and cancellous bones were measured. Results: The highest VMSs were generated by the abutment-free (Model C, Matrix) implant system on the implant fixture [static (32.36 Mpa), cyclic static (83.34 Mpa)], screw [static (16.85 Mpa), cyclic static (30.33 Mpa), oblique (57.46 Mpa)], and cortical bone [static (26.55), cyclic static (108.99 Mpa), oblique (47.8 Mpa)]. The lowest VMSs in the implant fixture, abutment, screw, and crown were associated with the binary alloy Roxolid [83–87% Ti and 13–17% Zr]. Conclusions: Abutment-free implant systems generate twice the stress on cortical bone than other abutment implant systems while producing the highest stresses on the fixture and screw, therefore demanding further clinical investigations. Roxolid, a binary alloy of titanium and zirconia, showed the least overall stresses in different loadings and directions.Keywords
This publication has 57 references indexed in Scilit:
- Fretting-corrosion at the Implant–Abutment Interface Simulating Clinically Relevant ConditionsDental Materials, 2024
- Three-dimensional finite element analysis of the biomechanical behaviour of different dental implants under immediate loading during three masticatory cyclesHeliyon, 2024
- Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interfaceJournal of Dentistry, 2022
- Additive manufacturing of titanium-based alloys- A review of methods, properties, challenges, and prospectsHeliyon, 2022
- Microstructure and mechanical properties of Titanium grade 23 produced by selective laser meltingArchives of Civil and Mechanical Engineering, 2021
- Finite element analysis and experimental evaluation on stress distribution and sensitivity of dental implants to assess optimum length and thread pitchComputer Methods and Programs in Biomedicine, 2020
- The effects of design parameters on mechanical failure of Ti-6Al-4V implants using finite element analysisEngineering Failure Analysis, 2020
- Influence of Different Abutment Designs on the Biomechanical Behavior of One-Piece Zirconia Dental Implants and Their Surrounding Bone: A 3D-FEAIRBM, 2019
- Three Dimensional Finite Element Analysis of Stress Distribution Around Implant with Straight and Angled Abutments in Different Bone QualitiesThe Journal of Indian Prosthodontic Society, 2013
- The influence of various occlusal materials on stresses transferred to implant‐supported prostheses and supporting bone: A three‐dimensional finite‐element studyJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005