Real-time Cherenkov emission portal imaging during CyberKnife®radiotherapy
Open Access
- 29 October 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (22) , N419-N425
Abstract
The feasibility of real-time portal imaging during radiation therapy, through the Cherenkov emission (CE) effect is investigated via a medical linear accelerator (CyberKnife(®)) irradiating a partially-filled water tank with a 60 mm circular beam. A graticule of lead/plywood and a number of tissue equivalent materials were alternatively placed at the beam entrance face while the induced CE at the exit face was imaged using a gated electron-multiplying-intensified-charged-coupled device (emICCD) for both stationary and dynamic scenarios. This was replicated on an Elekta Synergy(®) linear accelerator with portal images acquired using the iViewGT(™) system. Profiles across the acquired portal images were analysed to reveal the potential resolution and contrast limits of this novel CE based portal imaging technique and compared against the current standard. The CE resolution study revealed that using the lead/plywood graticule, separations down to 3.4 ± 0.5 mm can be resolved. A 28 mm thick tissue-equivalent rod with electron density of 1.69 relative to water demonstrated a CE contrast of 15% through air and 14% through water sections, as compared to a corresponding contrast of 19% and 12% using the iViewGT(™) system. For dynamic scenarios, video rate imaging with 30 frames per second was achieved. It is demonstrated that CE-based portal imaging is feasible to identify both stationary and dynamic objects within a CyberKnife(®) radiotherapy treatment field.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/F50053X/1)
- National Institutes of Health (R01CA109544)
This publication has 12 references indexed in Scilit:
- The physics of Cerenkov light production during proton therapyPhysics in Medicine & Biology, 2014
- Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real TimeInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2014
- Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dosePhysics in Medicine & Biology, 2014
- Imaging Cerenkov emission as a quality assurance tool in electron radiotherapyPhysics in Medicine & Biology, 2014
- Real-time in vivo Cherenkoscopy imaging during external beam radiation therapyJournal of Biomedical Optics, 2013
- Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x‐ray beamMedical Physics, 2013
- Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantomsPhysics in Medicine & Biology, 2013
- Three-dimensional Čerenkov tomography of energy deposition from ionizing radiation beamsOptics Letters, 2013
- Projection imaging of photon beams by the Čerenkov effectMedical Physics, 2012
- Time-gated Cherenkov emission spectroscopy from linear accelerator irradiation of tissue phantomsOptics Letters, 2012