RETRACTED ARTICLE: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution
Authors:
- 13 October 2006
- journal article
- retracted article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 32 (12) , 2053-2058
Abstract
To compare noninvasive cardiac output (CO)measurement obtained with a new thoracic electrical bioimpedance (TEB) device, using a proprietary modification of the impedance equation, with invasive measurement obtained via pulmonary artery thermodilution. Prospective, observational study. Surgical intensive care unit (ICU) of a university-affiliated community hospital. Seventy-four adult patients undergoing elective cardiac surgery with routine pulmonary artery catheter placement. None. Simultaneous paired CO and cardiac index (CI) measurements by TEB and thermodilution were obtained in mechanically ventilated patients upon admission to the ICU. For analysis of CI data the patients were subdivided into a hemodynamically stable group and a hemodynamically unstable group. The groups were analyzed using linear regression and tests of bias and precision. We found a significant correlation between thermodilution and TEB (r = 0.83; n< 0.001), accompanied by a bias of –0.01 l/min/m2 and a precision of ±0.57 l/min/m2 for all CI data pairs. Correlation, bias, and precision were not influenced by stratification of the data. The correlation coefficient, bias, and precision for CI were 0.86 (n< 0.001), 0.03 l/min/m2, and ±0.47 l/min/m2 in hemodynamically stable patients and 0.79 (n< 0.001), 0.06 l/min/m2, and ±0.68 l/min/m2 in hemodynamically unstable patients. Our results demonstrate a close correlation and clinically acceptable agreement and precision between CO measurements obtained with impedance cardiography using a new algorithm to calculate CO from variations in TEB, and those obtained with the clinical standard of care, pulmonary artery thermodilution, in hemodynamically stable and unstable patients after cardiac surgery.Keywords
This publication has 19 references indexed in Scilit:
- Lithium dilution cardiac output measurementCritical Care Medicine, 1997
- Impedance Cardiography Accurately Measures Cardiac Output During Exercise in Children With Cystic FibrosisChest, 1997
- Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilutionCritical Care Medicine, 1995
- Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimationCritical Care Medicine, 1994
- Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patientsCritical Care Medicine, 1993
- Noninvasive measurement of cardiac output using partial CO/sub 2/ rebreathingIEEE Transactions on Biomedical Engineering, 1988
- Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patientsCritical Care Medicine, 1986
- A new stroke volume equation for thoracic electrical bioimpedanceCritical Care Medicine, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Frequency of technical problems encountered in the measurement of pulmonary artery wedge pressureCritical Care Medicine, 1984