High performance liquid chromatographic determination of methylxanthines in canine serum, gastric and pancreatic juices
Authors:
- 1 September 1990
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 4 (5) , 209-213
Abstract
A convenient high performance liquid chromatographic method for the determination of methylxanthines in biological samples is described. Separation was achieved by reversed phase chromatography using a mobile phase consisting of tetrahydrofuran + methanol + 0.01M potassium dihydrogen phosphate, pH 3.5 (1:20:79, v/v/v), on a 7 μm C18 column and a C18 Lichrosorb precolumn at a flow rate of 0.8 mL/min. Levels varying from 0.25 – 16 mg/L could be detected by UV at 280 nm. In this range, standard curves were established for 4 methylxanthines: theobromine, paraxanthine, theophylline and caffeine in 4 media: mobile phase, serum, gastric and pancreatic juices, and were found to be linear (r ≥ 0.9975). Overall characteristics of the method were determined as: percent recovery (89.54%), accuracy (≥99.4%) and reproducibility (≥95%). Retention times ranged from 4.21 ± 0.01 (1‐methyluric acid) to 10.8 ± 0.03 min (caffeine). Animal experiments (5 and 10 mg/kg boluses) were used to determine caffeine half life in dog's blood (310 ± 46 and 453 ± 59 min, respectively) and its secretion into pentagastrin stimulated gastric juice (mean concentrations 2.51 and 6.04 mg/L; mean outputs 351 and 1206 μg/2.25 h; both statistically different at p < 0.001 level).Keywords
This publication has 15 references indexed in Scilit:
- Assessment of caffeine exposure: Caffeine content of beverages, caffeine intake, and plasma concentrations of methylxanthinesClinical Pharmacology & Therapeutics, 1986
- The Acute Effects of Coffee and Caffeine on Human Interdigestive Exocrine Pancreatic SecretionPancreas, 1986
- Improved micro-method for the high-performance liquid chromatographic determination of caffeine and paraxanthine in biological fluidsJournal of Chromatography B: Biomedical Sciences and Applications, 1984
- Epidemiology of pancreatic cancer1984
- Simultaneous determination of caffeine and its N-demethylated metabolites in umbilical cord plasma using high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1984
- Coffee and cancer of the pancreasBritish Journal of Cancer, 1981
- A Multifactorial Model for Pancreatic Cancer in ManJAMA, 1981
- Manual of Pharmacologic Calculations1981
- Dose-dependent kinetics of caffeine in ratsToxicology Letters, 1978
- An Improved Cannula for Gastric and Intestinal FistulasExperimental Biology and Medicine, 1941