Verification of the position of pedicle screws in lumbar spinal fusion
Authors:
- 1 March 1997
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 6 (2) , 125-128
Abstract
Medial or lateral pedicle screw penetration with the potential to affect neural structures in a well-known and frequent problem associated with posterior spinal fusion. We evaluated the placement of pedicle screws (n = 141) in 36 patients following posterior lumbar spinal fusion with Socon or Kluger instrumentation via a lateral transpedicular approach. The examination was based on CT and MR images performed after removal of the instrumentation, on average 1 year after implantation. We found seven pedicle screws with lateral cortical penetration of the pedicle and five screws with medial cortical penetration of the pedicle (8.5% pedicle penetration overall). No severe radicular complications accompanied these pedicle penetrations. The mean insertion angles of the pedicle screws at the L4 level were 22.6° and 23.1° for the left and the right side, respectively. At the L5 level the mean insertion angle was 20.5° on the left side and 21.5° on the right, and at the S1 level the mean angle was 16.2° on the left and 15.2° on the right. The results of this study indicate that the lateral transpedicular approach is a safe procedure for pedicle screw insertion.Keywords
This publication has 17 references indexed in Scilit:
- Accuracy of Pedicle Screw Placement in Lumbar Fusions by Plain Radiographs and Computed TomographySpine, 1995
- Biomechanische Überlegungen zur Anwendung von Fixateur interne Systemen bei WirbelsäuleneingriffenZeitschrift für Orthopädie und ihre Grenzgebiete, 1995
- Biomechanische Untersuchungen zweisegmentaler lumbosakraler Stabilisationen mittels Fixateur interne oder mit PMMA simulierten FusionenZeitschrift für Orthopädie und ihre Grenzgebiete, 1995
- Complications Associated with the Technique of Pedicle Screw Fixation A Selected Survey of ABS MembersSpine, 1993
- Complications of Lumbar Spinal Fusion with Transpedicular InstrumentationSpine, 1992
- Lagekontrolle von Pedikelschrauben nach instrumentierter dorsaler Fusion der LendenwirbelsäuleZeitschrift für Orthopädie und ihre Grenzgebiete, 1992
- Der Fixateur interne bei nicht-traumatischen Indikationen in der Wirbelsäulen-ChirurgieZeitschrift für Orthopädie und ihre Grenzgebiete, 1991
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990
- Spinal Pedicle Fixation: Reliability and Validity of Roentgenogram-Based Assessment and Surgical Factors on Successful Screw PlacementSpine, 1988
- Analysis of the Morphometric Characteristics of the Thoracic and Lumbar PediclesSpine, 1987