Study on the removal characteristics of different air pollution control devices for condensable particulate matter in coal-fired power plants
Authors:
- 18 January 2022
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (23) , 34714-34724
Abstract
This study reports the emissions of condensable particulate matter (CPM) and filterable particulate matter (FPM) in two coal-fired power plants with different air pollution control devices (APCDs). The mechanisms of CPM removed by existing APCDs in coal-fired power plants were explored, and a series of analyses were also carried out on the composition and characteristics of CPM. The results show that the removal efficiencies to CPM by electrostatic-bag-precipitator (EBP) and ESP are 77.34% and 79.23%, respectively, so the difference is not obvious because the interception filtration mechanisms of baghouses for CPM have less effect on CPM compared to FPM. The mechanism of EBP/ESP to remove CPM is mainly electrostatic adsorption and FPM’s adsorption. The concentration of CPM decreases when passing through WFGD. However, the WESP can increase the CPM in different ways. For example, the pollution of the circulation of the flushing fluid may cause the increase of CPM. In addition, CPM mainly includes three parts. The first part is organic fractions such as alkanes and esters; the second is the water-soluble ions that include SO42−, NH4+, and Cl−; and the third is Na, Ca, and other minerals. The research in this study is helpful to understand the impact of existing APCDs in coal-fired power plants on CPM and the sources of CPM. Graphical abstractKeywords
Funding Information
- National Natural Science Foundation of China (51922045, 52036003)
This publication has 33 references indexed in Scilit:
- Field Measurements on the Emission and Removal of PM2.5 from Coal-Fired Power Stations: 1. Case Study for a 1000 MW Ultrasupercritical Utility BoilerEnergy & Fuels, 2016
- Field Measurements on the Emission and Removal of PM2.5 from Coal-Fired Power Stations: 3. Direct Comparison on the PM Removal Efficiency of Electrostatic Precipitators and Fabric FiltersEnergy & Fuels, 2016
- Field Measurements on the Emission and Removal of PM2.5 from Coal-Fired Power Stations: 2. Studies on Two 135 MW Circulating Fluidized Bed Boilers Respectively Equipped with an Electrostatic Precipitator and a Hybrid Electrostatic Filter PrecipitatorEnergy & Fuels, 2016
- Influence of flue gas cleaning system on characteristics of PM2.5 emission from coal-fired power plantsInternational Journal of Coal Science & Technology, 2014
- Size, source and chemical composition as determinants of toxicity attributable to ambient particulate matterAtmospheric Environment, 2012
- Source attribution of urban smog episodes caused by coal combustionAtmospheric Research, 2008
- Characteristics of Inhalable Particulate Matter Concentration and Size Distribution from Power Plants in ChinaJournal of the Air & Waste Management Association, 2006
- Methods for Characterization of Composition of Fly Ashes from Coal-Fired Power Stations: A Critical OverviewEnergy & Fuels, 2005
- Formation and emission of fine particles from two coal-fired power plantsCombustion Science and Technology, 2002
- Fly Ash Collected from Electrostatic Precipitators: Microcrystalline Structures and the Mystery of the SpheresScience, 1976