Design of three-section microneedle towards low insertion force and high drug delivery amount using the finite element method
- 10 February 2023
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 27 (2) , 156-166
Abstract
A microneedle has been greatly recognized as one of the most promising devices for novel transdermal drug delivery system due to its capacity of piercing the protective stratum corneum with a minimally invasive and painless manner. During the past two decades, although numerous achievements have been made in the structure and material combination of microneedles, they mostly focus on the pharmacology and functionality of microneedles, and little is reported about how to design the shape of microneedles to reduce insertion force and especially improve penetration efficiency. Using the developed finite element method, we designed three-section microneedles (TSMN) with various sizes and evaluated their maximum insertion force, penetration efficiency, drug delivery amount and strength. The simulation results demonstrate that the well-designed TSMN with shaft width of 60 μm exhibits a lower maximum insertion force of 116.68 mN relative to 167.92 mN of conical microneedle and an effective penetration length of 81.6% relative to 71.38% of conical microneedle. Besides, the optimized TSMN with shaft width of 80 μm shows similar maximum insertion force and 2.3 times the drug delivery amount compared to conical microneedle. These excellent properties are attributed to the optimized design of the shape curve of TSMN sidewall. Such results may provide an inspiration of microneedle design for low insertion force and high penetration efficiency.Keywords
Funding Information
- Natural Science Foundation of China (92163216)
- Natural Science Foundation of Jiangsu Province (BK20180098)
- Youth Program of the Faculty of Agricultural Equipment of Jiangsu University (NZXB20210204)
- Open research fund of national laboratory of solid-state microstructures (M33042)
This publication has 19 references indexed in Scilit:
- Additive Manufacturing of Honeybee-Inspired Microneedle for Easy Skin Insertion and Difficult RemovalACS Applied Materials & Interfaces, 2018
- Effect of honeybee stinger and its microstructured barbs on insertion and pull forceJournal of the Mechanical Behavior of Biomedical Materials, 2017
- Influence of Array Interspacing on the Force Required for Successful Microneedle Skin Penetration: Theoretical and Practical ApproachesJournal of Pharmaceutical Sciences, 2013
- Quantifying the mechanical properties of human skin to optimise future microneedle device designComputer Methods in Biomechanics and Biomedical Engineering, 2012
- Numerical simulation of microneedles' insertion into skinComputer Methods in Biomechanics and Biomedical Engineering, 2011
- In vivocharacterization of the mechanical properties of human skin derived from MRI and indentation techniquesComputer Methods in Biomechanics and Biomedical Engineering, 2007
- The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experimentsMedical Engineering & Physics, 2005
- Influence of the hydrophobic and hydrophilic characteristics of sliding and slider surfaces on friction coefficient: in vivo human skin friction comparisonSkin Research and Technology, 2004
- Force Modeling for Needle Insertion Into Soft TissueIEEE Transactions on Biomedical Engineering, 2004
- Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture forceJournal of Biomechanics, 2004