ASTEC, COCOSYS, and LIRIC Interpretation of the Iodine Behavior in the Large-Scale THAI Test Iod-9
- 16 August 2010
- journal article
- research article
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 132 (11) , 112902
Abstract
The large-scale iodine test Iod-9 of the German Thermal hydraulics, Hydrogen, Aerosols, Iodine (THAI) program was jointly interpreted by means of post-test analyses within the THAI Circle of the Severe Accident Research NETwork (SARNET)/Work Package 16. In this test, molecular iodine was injected into the vessel dome of the THAI vessel to observe the evolution of its distribution between water, gas, and surfaces. The main processes addressed in Iod-9 are (a) the mass transfer of between the gas and the two sumps, (b) the iodine transport in the main sump when it is stratified and then mixed, and (c) the adsorption onto, and desorption from, the vessel walls in the presence and absence of wall condensation. The codes applied by the THAI Circle partners were the Accident Source Term Evaluation Code (ASTEC)-IODE (IRSN, Saint Paul Lez Durance, France), Containment Code System (COCOSYS)-Advanced Iodine Model (AIM) (GRS, Garching, Germany), and Library of Iodine Reactions in Containment (LIRIC; AECL, Chalk River, ON, Canada). ASTEC-IODE and the Advanced Iodine Model (AIM) are semi-empirical iodine models integrated in the lumped-parameter codes ASTEC and COCOSYS, respectively. With both codes multicompartment iodine calculations can be performed. LIRIC is a mechanistic iodine model for single stand-alone calculations. The simulation results are compared with each other and with the experimental measurements. Special issues that were encountered during this work were studied in more details: diffusion in the sump water, reaction with the steel of the vessel wall in gaseous and aqueous phases, and mass transfer from the gas to the sump. Iodine transport and behavior in THAI test Iod-9 are fairly well simulated by ASTEC-IODE, COCOSYS-AIM, and LIRIC in post-test calculations. The measured iodine behavior is well understood and all measured data are found to be consistent. The very slow iodine transport within the stratified main sump was simulated with COCOSYS only, in a qualitative way. Consequently, this work highlighted the need to improve modeling of (a) the wet iodine adsorption and the washdown from the walls, (b) the mass transfer between gas and sump, and (c) the reaction in the gaseous and aqueous phases. In any case, the analysis of the large-scale iodine test Iod-9 has been an important validation step for the codes applied.
Keywords
This publication has 8 references indexed in Scilit:
- Modeling of Iodine Radiochemistry in the ASTEC Severe Accident Code: Description and Application to FPT-2 PHEBUS TestNuclear Technology, 2010
- The ASTEC Integral Code for Severe Accident SimulationNuclear Technology, 2009
- COCOSYS and ASTEC Analyses of Iodine Multi-Compartment Tests in the ThAI-Facility2006
- LIRIC 3.2 an updated model for iodine behaviour in the presence of organic impuritiesRadiation Physics and Chemistry, 2001
- Kinetics of Gaseous Iodine Uptake onto Stainless Steel during Iodine-Assisted CorrosionNuclear Technology, 2001
- Corrosion of stainless steel by gaseous I2Journal of Nuclear Materials, 1999
- Iodine-steel reactions under severe accident conditions in light-water reactorsNuclear Engineering and Design, 1996
- Laboratory study of liquid-phase controlled volatilization rates in presence of wind wavesEnvironmental Science & Technology, 1978