Detection of Initial Yield and Onset of Failure in Bonded Posttensioned Concrete Beams
- 1 November 2012
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (6) , 966-974
Abstract
This paper discusses monitoring of bonded posttensioned (PT) concrete elements using the acoustic emission technique. In particular, a statistical pattern recognition technique based on a multivariate outlier analysis is presented to identify initial yielding and the onset of failure. Experimental tests on large-scale single-tendon bonded PT concrete beams, subjected to multiple load cycles, will be presented to validate the proposed monitoring system.Keywords
This publication has 24 references indexed in Scilit:
- Use of Interwire Ultrasonic Leakage to Quantify Loss of Prestress in Multiwire TendonsJournal of Engineering Mechanics, 2011
- Guided-wave Health Monitoring of Aircraft Composite Panels under Changing TemperatureJournal of Intelligent Material Systems and Structures, 2009
- An unsupervised learning algorithm for fatigue crack detection in waveguidesSmart Materials and Structures, 2009
- Monitoring Corrosion of Rebar Embedded in Mortar Using High-Frequency Guided Ultrasonic WavesJournal of Engineering Mechanics, 2009
- Monitoring Prestress Level in Seven Wire Prestressing Tendons by Inter Wire Ultrasonic Wave PropagationAdvances in Science and Technology, 2008
- Wavelet-based outlier analysis for guided wave structural monitoring: Application to multi-wire strandsJournal of Sound and Vibration, 2007
- Time series-based damage detection and localization algorithm with application to the ASCE benchmark structureJournal of Sound and Vibration, 2006
- Robust Clustering of Acoustic Emission Signals Using Neural Networks and Signal Subspace ProjectionsEURASIP Journal on Advances in Signal Processing, 2003
- Time Domain Reflectometry for Void Detection in Grouted Posttensioned BridgesTransportation Research Record: Journal of the Transportation Research Board, 2003
- Application of Wigner-Ville Transform to Evaluate Tensile Forces in Seven-Wire Prestressing StrandsJournal of Engineering Mechanics, 2002