Do more with Less: Improving High Parameter Cytometry Through Overnight Staining
Open Access
- 14 November 2022
- journal article
- research article
- Published by Wiley in Current Protocols
- Vol. 2 (11)
Abstract
Recent advances in flow cytometry have allowed high‐dimensional characterization of biological phenomena, enabling breakthroughs in a multitude of fields. Despite the appreciation of the unique properties of antigens and fluorophores in high‐parameter panel design, staining conditions are often standardized for short surface stains, regardless of antibody affinity or antigen accessibility. Here, we demonstrate how increasing antibody incubation times can lead to substantial improvements in sensitivity, maintaining specificity, and reducing background, while also significantly reducing the costs of high‐parameter cytometry panels. Furthermore, overnight staining reduces the influence of interexperimental variability, assisting accurate pooling over experiments over extended time courses. We provide guidance on how to optimize staining conditions for diverse antigens, including how different fixation strategies can affect epitope accessibility. Overnight staining can thus substantially improve the resolution, repeatability, and cost‐effectiveness of high‐parameter cytometry. © 2022 The Authors. Current Protocols published by Wiley Periodicals LLC.This article was corrected on 18 January 2023. See the end of the full text for details.Keywords
This publication has 11 references indexed in Scilit:
- Panel Optimization for High‐Dimensional Immunophenotyping Assays Using Full‐Spectrum Flow CytometryCurrent Protocols, 2021
- Improved method to retain cytosolic reporter protein fluorescence while staining for nuclear proteinsCytometry Part A, 2014
- A myriad of functions and complex regulation of the CCR7/CCL19/CCL21 chemokine axis in the adaptive immune systemCytokine & Growth Factor Reviews, 2013
- PE-Cy5.5 conjugates bind to the cells expressing mouse DEC205/CD205Journal of Immunological Methods, 2012
- CCR7 and its ligands: balancing immunity and toleranceNature Reviews Immunology, 2008
- Optimizing a Multicolor Immunophenotyping AssayClinics In Laboratory Medicine, 2007
- Factors affecting the antigen-antibody reaction2007
- Phosphorothyoate oligodeoxynucleotides block nonspecific binding of Cy5 conjugates to monocytesJournal of Immunological Methods, 2005
- Selecting fluorochrome conjugates for maximum sensitivityCytometry Part A, 2004