Non‐extractive procedure followed by LC/APCI MS/MS analysis of trimetazidine in plasma samples for assessing bioequivalence of immediate/modified release formulations
- 14 January 2005
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 19 (7) , 549-555
Abstract
Trimetazidine and internal standard [1‐(2,4,5‐trimethoxybenzyl)piperazine] were isolated from plasma by protein precipitation with trifluoroacetic acid. The neutralized supernatant was separated on a C8 column with methanol–aqueous 0.11% triethylamine adjusted to pH 3.3 with formic acid (1:4, v/v) at a flow rate of 0.85 mL/min. The separation was achieved within 8 min and the column effluent was transferred into an ion trap analyzer via an atmospheric pressure chemical ionization interface. The mass analyzer was used in the selected reaction monitoring mode, to enhance detection selectivity. The method was fully validated with a quantitation limit for trimetazidine of 1.5 ng/mL. The method was successfully applied to assess bioequivalence of two immediate and two modified commercially available pharmaceutical formulations containing 20 and 35 mg of trimetazidine, respectively. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 10 references indexed in Scilit:
- UTILITY OF SOME π-ACCEPTORS FOR THE SPECTROPHOTOMETRIC DETERMINATION OF TRIMETAZIDINE HYDROCHLORIDEAnalytical Letters, 2002
- HIGH THROUGHPUT ASSAY METHOD FOR THE QUANTITATION OF TRIMETAZIDINE IN HUMAN PLASMA BY LC/MS, WITH SELECTED REACTION MONITORINGJournal of Liquid Chromatography & Related Technologies, 2001
- Stability indicating HPTLC determination of Trimetazidine as bulk drug and in pharmaceutical formulationsJournal of Pharmaceutical and Biomedical Analysis, 2001
- Trimetazidine: stability indicating RPLC assay methodJournal of Pharmaceutical and Biomedical Analysis, 2001
- Analytical applications of chemiluminogenic reactionsAnalytica Chimica Acta, 2000
- The pH-Partition Profile of the Anti-Ischemic Drug Trimetazidine May Explain Its Reduction of Intracellular AcidosisPharmaceutical Research, 1999
- Use of high-performance liquid chromatography with photodiode-array UV detection for the creation of a 600-compound library application to forensic toxicologyJournal of Chromatography A, 1997
- Identification of trimetazidine metabolites in human urine and plasmaXenobiotica, 1996
- Determination of trimetazidine in biological fluids by gas chromatography-mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1989
- Trace determination of trimetazidine in plasma by high-performance liquid chromatography using fluorescence detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1981