Preconcentration of Heavy Metals and Matrix Elimination using Silica Gel Chemically Modified with 2,3‐Dihydroxybenzaldehyde
- 1 February 2007
- journal article
- research article
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 42 (4) , 879-895
Abstract
Many direct methods cannot easily be used to measure analytes such as Cd(II), Cu(II), Ni(II), Pb(II), and Zn(II) ions in sea and river water since these elements are present at very low concentration and the sample has a very complex matrix. In this study a method was developed to preconcentrate these ions by solid phase extraction within a column system using a newly synthesised 2,3‐dihydroxy benzaldehyde modified silica gel (SGDHB). Different parameters, such as pH, resin amount, eluent type, eluent volume, sample flow rate, preconcentration factors, and resin capacity were determined for the preconcentration of metal ions with the resin. Samples (125–500 ml) containing metal ions were passed through the column filled with SGDHB resin so that metal ions were retained on the column. The preconcentrated analytes were then eluted with 15 mL of 0.1 M HCl. The metal concentrations in the eluate were measured by FAAS. A sample and eluent flow rate of 1.12 and 0.56 ml/min respectively was used. Estimates of accuracy, precision, and detection limits were determined. In addition, analysis of the CRM LGC 6156 harbor sediment was undertaken, using the resin to isolate the analytes from potential interferences. Good agreement with certified values was obtained, indicating that the method is equally applicable to the analysis of water samples and to digests of solid materials.Keywords
This publication has 33 references indexed in Scilit:
- Celtek clay as sorbent for separation–preconcentration of metal ions from environmental samplesJournal of Hazardous Materials, 2006
- Multi-element preconcentration of heavy metal ions from aqueous solution by APDC impregnated activated carbonTalanta, 2005
- Solid-Phase Extraction and Spectrophotometric Determination of Trace Amounts of Mercury in Natural SamplesMicrochimica Acta, 2005
- Speciation of Aluminum in Drink Samples by 8-Hydroxyquinoline Loaded Silylanization Silica Gel Microcolumn Separation with Off-Line ICP-MS DetectionJournal of Agricultural and Food Chemistry, 2004
- On-line liquid–liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural watersTalanta, 2004
- 8-Hydroxyquinoline anchored to silica gel via new moderate size linker: synthesis and applications as a metal ion collector for their flame atomic absorption spectrometric determinationTalanta, 2003
- Solid phase extraction of trace elementsSpectrochimica Acta Part B: Atomic Spectroscopy, 2003
- Cellulose functionalized with 8-hydroxyquinoline: new method of synthesis and applications as a solid phase extractant in the determination of metal ions by flame atomic absorption spectrometryAnalytica Chimica Acta, 2003
- Solid phase extractive preconcentration of thorium onto 5,7-dichloroquinoline-8-ol modified benzophenoneTalanta, 2002
- Study and application of a method for the determination of metallic elements by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a FI systemAnalytical and Bioanalytical Chemistry, 1998