Abstract
Magnetic resonance‐based wireless power transfer (WPT) system offers a promising solution to provide power for implantable spinal cord stimulator (SCS). To meet with the clinical requirements, the SCS‐WPT system should have high transfer efficiency and long transfer distance. As the topology of the resonant network will directly affect the transfer efficiency and output power of the WPT system, a new resonant network, series‐parallel and series (S‐PS), is selected in this work. The performance of WPT system with S‐PS resonant network has been compared with those with the classic resonance networks, it is concluded that S‐PS is the suitable resonant network for the WPT system in a wide range of load. Finally, an SCS‐WPT prototype with S‐PS resonant network is built with detailed parameter design to verify the correctness of theoretical analysis. The system efficiency is up to 68.4% at a coil separation of 50 mm.Keywords
Funding Information
- National Natural Science Foundation of China (51677074)
This publication has 30 references indexed in Scilit:
- Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical ImplantIEEE Transactions on Industrial Electronics, 2013
- A Wireless Magnetic Resonance Energy Transfer System for Micro Implantable Medical SensorsSensors, 2012
- Managing Chronic Pain With Spinal Cord StimulationMount Sinai Journal of Medicine: A Journal of Translational and Personalized Medicine, 2012
- Analysis, Design, and Control of a Transcutaneous Power Regulator for Artificial HeartsIEEE Transactions on Biomedical Circuits and Systems, 2009
- A Frequency Control Method for Regulating Wireless Power to Implantable DevicesIEEE Transactions on Biomedical Circuits and Systems, 2008
- Novel technology for the provision of power to implantable physiological devicesJournal of Applied Physiology, 2007
- Living With the Jarvik 2000: A Five‐Plus Year ExperienceArtificial Organs, 2006
- Complex Regional Pain Syndromes (Reflex Sympathetic Dystrophy and Causalgia) and Spinal Cord StimulationPain Medicine, 2006
- Electric power-generating system using magnetic coupling for deeply implanted medical electronic devicesIEEE Transactions on Magnetics, 2002
- Design of transcutaneous energy transmission system using a series resonant converterIEEE Transactions on Power Electronics, 1992