Background radiation in low-pressure flashlamps from ablation phenomena
Authors:
- Joaquin Sanchez SanzJSJoaquin Sanchez Sanz
- Jose M. Guerra PerezJPJose M. Guerra Perez
- 1 January 1987
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 26 (1) , 127-130
Abstract
Radiation emitted from flashlamps operating in a wall ablation regime consists mainly of background radiation, the observed line radiation from wall elements being only an indicator of the transition to the ablative regime. We analyze the origin of that background radiation. It does not come from a rise in temperature, but from an increase in electron concentration caused by the ionization of ablation elements. In LTE conditions (Ne = 3 × 1023m-3,T = 2 × 104 K), we determine temperatures and concentrations in the tube axis and in the discharge border. Ablation products concentrate mainly near the walls where the temperature is lower.Keywords
This publication has 7 references indexed in Scilit:
- Low-pressure flashlamps: influence of the wall ablation phenomena on their output characteristicApplied Optics, 1985
- High-energy dye laser pumped by wall-ablation lampsApplied Physics A, 1978
- Ablative flashlamps for high peak power dye lasersApplied Optics, 1977
- Optimization of pulsed UV radiation from linear flashtubesJournal of Physics E: Scientific Instruments, 1975
- Ablative Light SourcesApplied Optics, 1968
- 7.5 - A quartz ablating lamp for u+C3678ltraviolet pumping and repetition-rate pumpingIEEE Journal of Quantum Electronics, 1967
- Transformation of Observed Radiances into Radial Distribution of the Emission of a Plasma*Journal of the Optical Society of America, 1961