Cerebral Hemoglobin and Optical Pathlength Influence Near-Infrared Spectroscopy Measurement of Cerebral Oxygen Saturation
Authors:
- 1 June 1997
- journal article
- neurosurgical anesthesia
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 84 (6) , 1297-1305
Abstract
Near-infrared spectroscopy (NIRS) is a noninvasive optical technique to monitor cerebral oxygen saturation at the bedside. Despite its applicability, NIRS has had limited clinical use because of concerns about accuracy, noted by intersubject variability in slope and intercept of the line between NIRS- and weighted-average arterial-cerebrovenous saturation (SMO2). This study evaluated transcranial optical pathlength and cerebral hemoglobin concentration as sources for this intersubject variability. Experiments were performed in an in vitro brain model and in piglets. Optical pathlength and cerebral hemoglobin concentration were measured by time-resolved spectroscopy (TRS). NIRS and TRS were recorded in the model, as perfusate blood saturation was varied (0%-100%) at several hemoglobin concentrations, and in piglets, as SMO2 was varied (15%-90%) before and after hemodilution. In the model, hemoglobin concentration significantly altered the NIRS versus blood saturation line slope and intercept, as well as optical pathlength. In piglets (before hemodilution), there was significant intersubject variability in NIRS versus SMO2 line slope (0.73-1.4) and intercept (-24 to 36) and in transcranial optical pathlength (13.4-16 cm) and cerebral hemoglobin concentration (0.58-1.1 g/dL). By adjusting the NIRS algorithm with optical pathlength or cerebral hemoglobin measurements, intersubject variability in slope (0.9-1.2) and intercept (-9 to 18) decreased significantly. Hemodilution significantly changed NIRS versus SMO2 line slope and intercept, as well as transcranial optical pathlength and cerebral hemoglobin concentration (before versus after hemodilution: slope 0.9 vs 0.78, intercept 13 vs 19, pathlength 13.9 vs 15.6 cm, cerebral hemoglobin 0.98 vs 0.73 g/dL). By adjusting the NIRS algorithm with the cerebral hemoglobin measurements, slope and intercept remained unchanged by hemodilution. These data indicate that intersubject variability in NIRS originates, in part, from biologic variations in transcranial optical pathlength and cerebral hemoglobin concentration. Instruments to account for these factors may improve NIRS cerebral oxygen saturation measurements. (Anesth Analg 1997;84:1297-305)Keywords
This publication has 23 references indexed in Scilit:
- A dynamic phantom brain model for near-infrared spectroscopyPhysics in Medicine & Biology, 1995
- An observational study of near-infrared spectroscopy during carotid endarterectomyJournal of Neurosurgery, 1995
- Light-reflective cerebral oximetry and jugular bulb venous oxygen saturation during carotid endarterectomyBritish Journal of Surgery, 1994
- Cerebral oxygen metabolism during hypothermic circulatory arrest in humansJournal of Neurosurgery, 1993
- The Influence of Intravascular Volume Expansion on Cerebral Blood Flow and Blood Volume in Normal RatsAnesthesiology, 1993
- Fluctuations in cerebral oxygenation and blood volume during endotracheal suctioning in premature infantsThe Journal of Pediatrics, 1992
- Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans.Stroke, 1991
- Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamicsCritical Care Medicine, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- In situ studies of oxidative energy metabolism during transient cortical ischemia in catsExperimental Neurology, 1976