Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements
Authors:
- Dominic W. HillDHDominic W. Hill
- Anurag BeheraABAnurag Behera
- Octave EtardOEOctave Etard
- Yuqian ZhangYZYuqian Zhang
- Alexandra Tran-Van-MinhATAlexandra Tran-Van-Minh
- Alexander RueschARAlexander Ruesch
- Lior NessLNLior Ness
- Chloe MaineCMChloe Maine
- Amir Salehi LashkajaniALAmir Salehi Lashkajani
- Veronika ParfentyevaVPVeronika Parfentyeva
- Navjit SinghNSNavjit Singh
- Alexander AntrobusAAAlexander Antrobus
Open Access
- 30 March 2026
- journal article
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (02) , 1-23
Abstract
SignificanceAchieving adequate brain sensitivity remains a significant obstacle to noninvasive optical measurements of pulsatile cerebral blood flow. Increasing source-detector separation (SDS), utilizing time-of-flight (ToF) information, and/or increasing acquisition frequency can increase brain sensitivity. However, optimizing these parameters is nontrivial and must balance the need to achieve sufficient signal-to-noise ratio.AimWe aim to guide hardware optimization by evaluating the benefits of ToF gating, autocorrelation time-lag gating, and increased source-detector separation in recovering pulsatile cerebral blood flow.ApproachMonte Carlo simulations of ToF-resolved pulsatile blood flow index at 1064 nm were performed. A simulation and analysis pipeline is presented and validated against phantom and in vivo measurements.ResultsBrain sensitivity deteriorates for autocorrelation time-lags >1 to 10 μs. Continuous-wave diffuse correlation spectroscopy (CW-DCS) at 40 mm SDS achieves equivalent brain sensitivity to time-resolved measurements with a 1.2 ns ToF gate. For median adult brain depths, a 31 mm SDS (CW-DCS), 35 mm SDS (speckle contrast optical spectroscopy), or 0.9 ns ToF are needed for brain-dominated signals. For the 85th percentile of brain depth, these thresholds increase to 40 mm, 46 mm, and 1.2 ns, respectively.ConclusionsWe quantitatively compare source-detector separation, ToF gating, and acquisition frequency and identify crucial performance requirements for clinically viable optical monitors of cerebral blood flow.Keywords
This publication has 75 references indexed in Scilit:
- Monte Carlo Simulation of Photon Migration in 3D Turbid Media Accelerated by Graphics Processing UnitsOptics Express, 2009
- Diffuse optical monitoring of hemodynamic changes in piglet brain with closed head injuryJournal of Biomedical Optics, 2009
- Optical properties of fat emulsionsOptics Express, 2008
- White Monte Carlo for time-resolved photon migrationJournal of Biomedical Optics, 2008
- Effects of measurement method, wavelength, and source-detector distance on the fast optical signalNeuroImage, 2006
- Diffuse optical correlation tomography of cerebral blood flow during cortical spreading depression in rat brainOptics Express, 2006
- Cerebral hemodynamics evaluation by near-infrared time-resolved spectroscopy: Correlation with simultaneous positron emission tomography measurementsNeuroImage, 2006
- Fast calculation of fluorescence correlation data with asynchronous time-correlated single-photon countingOptics Express, 2003
- Scattering and Imaging with Diffusing Temporal Field CorrelationsPhysical Review Letters, 1995
- MCML—Monte Carlo modeling of light transport in multi-layered tissuesComputer Methods and Programs in Biomedicine, 1995