Cervical Pedicle Screw Insertion Using the Technique with Direct Exposure of the Pedicle by Laminoforaminotomy
Authors:
Open Access
- 1 January 2012
- journal article
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 52 (5) , 459-465
Abstract
To present the accuracy and safety of cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy. We retrospectively reviewed 12 consecutive patients. A total of 104 subaxial cervical pedicle screws in 12 patients had been inserted. We also assessed the clinical and radiological outcomes and analyzed the direction and grade of pedicle perforation (grade 0: no perforation, 1: 50% of screw diameter) on the postoperative vascular-enhanced computed tomography scans. Grade 2 and 3 were considered as incorrect position. The correct position was found in 95 screws (91.3%); grade 0-75 screws, grade 1-20 screws and the incorrect position in 9 screws (8.7%); grade 2-6 screws, grade 3-3 screws. There was no neurovascular complication related with cervical pedicle screw insertion. This technique (technique with direct exposure of the pedicle by laminoforaminotomy) could be considered relatively safe and easy method to insert cervical pedicle screw.Keywords
This publication has 38 references indexed in Scilit:
- Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placementJournal of Neurosurgery: Spine, 2010
- Clinical accuracy of 3D fluoroscopy–assisted cervical pedicle screw insertionJournal of Neurosurgery: Spine, 2008
- Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical techniqueSurgical and Radiologic Anatomy, 2003
- Complications of Pedicle Screw Fixation in Reconstructive Surgery of the Cervical SpineSpine, 2000
- One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systemsJournal of Neurosurgery: Spine, 1999
- Use of Cervicothoracic Junction Pedicle Screws for Reconstruction of Complex Cervical Spine PathologySpine, 1998
- Pedicle Screw Fixation for Nontraumatic Lesions of the Cervical SpineSpine, 1997
- Morphometric Evaluation of Lower Cervical Pedicle and Its ProjectionSpine, 1997
- THE POSTERIOR SURGICAL APPROACH TO THE CERVICAL SPINENeuroimaging Clinics Of North America, 1995
- Transpedicular Screw Fixation for Traumatic Lesions of the Middle and Lower Cervical SpineJournal of Spinal Disorders, 1994