Objectives The aim of this study was to investigate the effect of the temporal resolution (T res) and acquisition duration (AD) on the measurement accuracy of contrast concentration–time curves (CTCs), and derived phenomenological and pharmacokinetic parameter values, in a dynamic contrast-enhanced MRI experiment using a novel phantom test device. Materials and methods ‘Ground truth’ CTCs were established using a highly precise optical imaging system. These precisely known CTCs were produced in an anthropomorphic environment, which mimicked the male pelvic region, and presented to the MRI scanner for measurement. The T res was varied in the range [2–24.4 s] and the AD in the range [30–600 s], and the effects on the measurement accuracy were quantified. Results For wash-in parameter measurements, large underestimation errors (up to 40%) were found using T res values ≥16.3 s; however, the measured wash-out rate did not vary greatly across all T res values tested. Errors in derived K trans and v e values were below 14 and 12% for acquisitions with {T res ≤ 8.1 s, AD ≥ 360 s} and {T res ≤ 16.3 s, AD ≥ 360 s}, respectively, but increased dramatically outside these ranges. Conclusions Errors in measured wash-in, wash-out, K trans, and v e parameters were minimised using T res ≤ 8.1 s and AD ≥ 360 s, with large errors recorded outside of this range.Keywords
Funding Information
- Irish Cancer Society (CRS13KNI)
This publication has 32 references indexed in Scilit:
- Classic models for dynamic contrast‐enhanced MRINMR in Biomedicine, 2013
- Overview of Dynamic Contrast-Enhanced MRI in Prostate Cancer Diagnosis and ManagementAmerican Journal of Roentgenology, 2012
- Effect of motion on the ADC quantification accuracy of whole-body DWIBSMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- The effect of motion correction on pharmacokinetic parameter estimation in dynamic-contrast-enhanced MRIPhysics in Medicine & Biology, 2011
- The precision of pharmacokinetic parameters in dynamic contrast-enhanced magnetic resonance imaging: the effect of sampling frequency and durationPhysics in Medicine & Biology, 2011
- Dynamic contrast-enhanced MRI and MR diffusion imaging to distinguish between glandular and stromal prostatic tissuesMagnetic Resonance Imaging, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- Wash‐in rate on the basis of dynamic contrast‐enhanced MRI: Usefulness for prostate cancer detection and localizationJournal of Magnetic Resonance Imaging, 2005
- Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a useful modality for the precise detection and staging of early prostate cancerThe Prostate, 2004