Implant Design Affects Knee Arthroplasty Kinematics during Stair-stepping
Authors:
- Scott A BanksSBScott A Banks
- W Andrew HodgeWHW Andrew Hodge
- 1 September 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 426 (426) , 187-193
Abstract
Knee implant motions have a direct influence on patient function and implant longevity. The purpose of this study was to determine if there were consistent differences in knee motions among three groups of knee implants. Two hundred thirteen knees in 173 patients, with 25 implant designs, were studied using fluoroscopy during stair-stepping. All knee implants were assigned to one of three groups based on the design: fixed-bearing posterior-stabilized, fixed-bearing posterior cruciate-retaining, and mobile-bearing. All types of implants had the same pattern of internal/external rotations, but different designs had different anteroposterior translations. Seventy-five percent of posterior-stabilized knee implants had a medial center of rotation, indicating posterior femoral translation with flexion. Sixty-three percent of cruciate-retaining fixed-bearing knee implants had a lateral center of rotation. Eighty-six percent of mobile-bearing knee implants had a lateral center of rotation, indicating anterior femoral translation with flexion. Knee motion in patients with successful total knee arthroplasties is related directly to the constraints of the implant design.Keywords
This publication has 31 references indexed in Scilit:
- Knee Motions During Maximum Flexion in Fixed and Mobile-Bearing ArthroplastiesClinical Orthopaedics and Related Research, 2003
- Weight‐bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructionsKnee Surgery, Sports Traumatology, Arthroscopy, 2002
- In vivo kinematics of total knee arthroplasty: Flat compared with concave tibial joint surfaceJournal of Orthopaedic Research, 2000
- The cruciate ligaments in total knee arthroplastyThe Journal of Arthroplasty, 2000
- In Vivo Knee Kinematics Derived Using an Inverse Perspective TechniqueClinical Orthopaedics and Related Research, 1996
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Kinematics of successful knee prostheses during weight‐bearing: Three‐dimensional movements and positions of screw axes in the Tricon‐M and Miller‐Galante designsKnee Surgery, Sports Traumatology, Arthroscopy, 1994
- Abnormal kinematics of the artificial knee: Roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS kneesActa Orthopaedica, 1991
- Posterior cruciate ligament balancing during total knee arthroplastyThe Journal of Arthroplasty, 1988
- Use of cardan angles to locate rigid bodies in three-dimensional spaceMedical & Biological Engineering & Computing, 1987