Inter-Day Glycemic Variability Assessed by Continuous Glucose Monitoring in Insulin-Treated Type 2 Diabetes Patients on Hemodialysis
Authors:
- 1 October 2010
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 12 (10) , 749-753
Abstract
Background: Type 2 diabetes patients on chronic hemodialysis have a high prevalence of cardiovascular complications and often show a poor glycemic control. Single-spot glycemic measurements are not always meaningful, and the hemoglobin A1c (HbA1c) value does not reflect short-term variations in glucose metabolism in this patient category. Therefore, to better understand their metabolic balance, we studied a group of diabetes patients on hemodialysis by a continuous glucose monitoring (CGM) system. Methods: Twelve insulin-treated type 2 diabetes patients on hemodialysis were studied by a microdialysis-based subcutaneous glucose sensor over a period of 2 days, including the dialysis day (HD) and the following inter-dialytic period (“free” day [FD]). Results: The mean 24-h glycemic value, the mean amplitude of glucose excursions, and the SD of mean glucose were significantly higher in the HD than the FD (186 ± 50 vs. 154 ± 25 mg/dL, P < 0.05; 75 ± 22 vs. 56 ± 15 mg/dL, P < 0.05; and 57 ± 26 vs. 35 ± 11 mg/dL, P < 0.05, respectively). Considering the 48-h recording, there was a direct correlation between the mean glucose concentration and the HbA1c ( r = 0.47, P < 0.05), whereas no association was observed between the measures of glucose variability and HbA1c. Conclusions: Insulin-treated diabetes patients on hemodialysis showed different glucose profiles between the HD and the FD. In particular, in the HD they have had an increased glycemic variability, which may represent an adjunctive risk factor for cardiovascular complications. Therefore the use of a CGM system, as a means of assessing the measures of glycemic variability, could improve the management of insulin therapy in these patients.Keywords
This publication has 23 references indexed in Scilit:
- Intensive Blood Glucose Control and Vascular Outcomes in Patients with Type 2 DiabetesThe New England journal of medicine, 2008
- Oscillating Glucose Is More Deleterious to Endothelial Function and Oxidative Stress Than Mean Glucose in Normal and Type 2 Diabetic PatientsDiabetes, 2008
- Acute Glucose Fluctuations and Chronic Sustained Hyperglycemia as Risk Factors for Cardiovascular Diseases in Patients with Type 2 DiabetesHormone and Metabolic Research, 2007
- A1C and Survival in Maintenance Hemodialysis PatientsDiabetes Care, 2007
- Adequacy of Glycemic Control in Hemodialysis Patients With DiabetesDiabetes Care, 2006
- Activation of Oxidative Stress by Acute Glucose Fluctuations Compared With Sustained Chronic Hyperglycemia in Patients With Type 2 DiabetesJAMA, 2006
- Defining the Relationship Between Plasma Glucose and HbA1cDiabetes Care, 2002
- Limitations of Conventional Methods of Self-Monitoring of Blood GlucoseDiabetes Care, 2001
- Retinopathy and Nephropathy in Patients with Type 1 Diabetes Four Years after a Trial of Intensive TherapyNew England Journal of Medicine, 2000
- Glycated Proteins as Indices of Glycaemic Control in Diabetic Patients with Chronic Renal FailureDiabetic Medicine, 1996