Point-of-Care Analyte Quantification and Digital Readout via Lysate-Based Cell-Free Biosensors Interfaced with Personal Glucose Monitors
- 21 October 2021
- journal article
- letter
- Published by American Chemical Society (ACS) in ACS Synthetic Biology
- Vol. 10 (11) , 2862-2869
Abstract
Field-deployable diagnostics based on cell-free systems have advanced greatly, but on-site quantification of target analytes remains a challenge. Here we demonstrate that Escherichia coli lysate-based cell-free biosensors coupled to a personal glucose monitor (PGM) can enable on-site analyte quantification, with the potential for straightforward reconfigurability to diverse types of analytes. We show that analyte-responsive regulators of transcription and translation can modulate the production of the reporter enzyme β-galactosidase, which in turn converts lactose into glucose for PGM quantification. Because glycolysis is active in the lysate and would readily deplete converted glucose, we decoupled enzyme production and glucose conversion to increase the end point signal output. However, this lysate metabolism did allow for one-pot removal of glucose present in complex samples (like human serum) without confounding target quantification. Taken together, our results show that integrating lysate-based cell-free biosensors with PGMs enables accessible target detection and quantification at the point of need.Keywords
All Related Versions
Funding Information
- Georgia Institute of Technology
- National Institute of Biomedical Imaging and Bioengineering (R01EB022592)
This publication has 38 references indexed in Scilit:
- Toehold Switches: De-Novo-Designed Regulators of Gene ExpressionCell, 2014
- Using the Widely Available Blood Glucose Meter to Monitor Insulin and HbA1cJournal of Diabetes Science and Technology, 2014
- Evidence-based interventions for improvement of maternal and child nutrition: what can be done and at what cost?The Lancet, 2013
- Biomarkers in nutrition: new frontiers in research and applicationAnnals of the New York Academy of Sciences, 2013
- Target-Responsive “Sweet” Hydrogel with Glucometer Readout for Portable and Quantitative Detection of Non-Glucose TargetsJournal of the American Chemical Society, 2013
- Portable and Quantitative Detection of Protein Biomarkers and Small Molecular Toxins Using Antibodies and Ubiquitous Personal Glucose MetersAnalytical Chemistry, 2012
- Using Commercially Available Personal Glucose Meters for Portable Quantification of DNAAnalytical Chemistry, 2012
- Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targetsNature Chemistry, 2011
- Energizing cell‐free protein synthesis with glucose metabolismBiotechnology and Bioengineering, 2005
- Infection by Shiga Toxin-Producing Escherichia coli : An OverviewMolecular Biotechnology, 2004