Reduction of B1 sensitivity in selective single‐slab 3d turbo spin echo imaging with very long echo trains
Authors:
- Jaeseok ParkJPJaeseok Park
- John P. MuglerJMJohn P. Mugler
Open Access
- 7 July 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (4) , 1060-1066
Abstract
Single‐slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is vulnerable to image degradation in the presence of spatially varying B1 amplitudes. In this work we develop a B1 inhomogeneity‐reduced version of single‐slab 3D turbo/fast SE imaging based on the hypothesis that it is critical to achieve spatially uniform excitation. Slab selection was performed using composite adiabatic selective excitation wherein magnetization is tipped into the transverse plane by a nonselective adiabatic‐half‐passage pulse and then slab is selected by a pair of selective adiabatic‐full‐passage pulses. Simulations and experiments were performed to evaluate the proposed technique and demonstrated that this approach is a simple and efficient way to reduce B1 sensitivity in single‐slab 3D turbo/fast SE imaging with very long echo trains. Magn Reson Med, 2009.Keywords
Funding Information
- Ministry of Health & Welfare, Republic of Korea (the Korea Health 21 R&D Project (A085136))
- Yonsei University, Germany (faculty research grant (6-2008-0023))
This publication has 16 references indexed in Scilit:
- B1‐insensitive fast spin echo using adiabatic square wave enabling of the echo train (SWEET) excitationMagnetic Resonance in Medicine, 2008
- Fast 3D radiofrequency field mapping using echo‐planar imagingMagnetic Resonance in Medicine, 2006
- Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrastMagnetic Resonance in Medicine, 2006
- Magnetic resonance imaging of the upper abdomen using a free‐breathing T2‐weighted turbo spin echo sequence with navigator triggered prospective acquisition correctionJournal of Magnetic Resonance Imaging, 2005
- Adiabatic RARE imagingNMR in Biomedicine, 2003
- Single‐shot, B1‐insensitive slice selection with a gradient‐modulated adiabatic pulse, BISS‐8Magnetic Resonance in Medicine, 1996
- A reduced power selective adiabatic spin‐echo pulse sequenceMagnetic Resonance in Medicine, 1991
- Optimization of modulation functions to improve insensitivity of adiabatic pulses to variations in B1 magnitudeJournal of Magnetic Resonance (1969), 1988
- Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equationPhysical Review A, 1985
- Composite pulses constructed by a recursive expansion procedureJournal of Magnetic Resonance (1969), 1983