A swept-scanning mode for estimation of blood velocity in the microvasculature
Authors:
- R.H. SilvermanRSR.H. Silverman
- R.J. FornarisRFR.J. Fornaris
- D.J. ColemanDCD.J. Coleman
- K.W. FerraraKFK.W. Ferrara
- 1 November 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 45 (6) , 1437-1440
Abstract
In contrast to previous systems in which an ultrasonic pulse was repeatedly directed to a discrete line of sight, a new method has been developed to continuously scan over a region in order to rapidly assess blood velocities in superficial small blood vessels. Using this technique, which we call swept-scan, a high frequency transducer can rapidly translate across a region of interest, and sensitive maps of blood velocity in small blood vessels can be constructed. This system has been applied to flow mapping in the anterior segment of the eye, which is clinically significant in cases of trauma and glaucoma. No previous imaging technique has been capable of estimating blood velocities within this region in a clinically useful manner. With this new technique, each 2-D scan of the eye can be obtained in an interval on the order of 1 second, and blood flow through the iris and ciliary body can be detected in vessels as small as 40 microns. A major implication of this new technique is that a wall filter can be applied continuously to the return from all regions, thus eliminating the transient response that occurs along each line of sight in traditional Doppler systems.Keywords
This publication has 11 references indexed in Scilit:
- Ultrasonic mapping of the microvasculature: signal alignmentUltrasound in Medicine & Biology, 1998
- Assessment of Human Ocular HemodynamicsSurvey of Ophthalmology, 1998
- Surgical vs Medical Management of Chronic Open-angle GlaucomaAmerican Journal of Ophthalmology, 1996
- Eye injuries in athletics and recreationSurvey of Ophthalmology, 1996
- Color Doppler ultrasound imaging of theeye and orbitSurvey of Ophthalmology, 1996
- Ocular blood flow measurement.British Journal of Ophthalmology, 1994
- Clinical Use of Ultrasound BiomicroscopyOphthalmology, 1991
- Ciliary Vasoconstriction After Topical Adrenergic DrugsAmerican Journal of Ophthalmology, 1990
- Real time ophthalmic ultrasonography and biometry: R. S. Koplin, M. Gersten and B. Hodes. Slack Inc., Thorofare, NJ, 1984, $24.50Ultrasound in Medicine & Biology, 1987
- Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique1985