Manufacturing of patient‐specific optically accessible airway models by fused deposition modeling
Authors:
- Mathias VermeulenMVMathias Vermeulen
- Tom ClaessensTCTom Claessens
- Benjamin Van Der SmissenBSBenjamin Van Der Smissen
- Cedric S. Van HolsbekeCHCedric S. Van Holsbeke
- Jan W. De BackerJBJan W. De Backer
- Peter Van RansbeeckPRPeter Van Ransbeeck
- Pascal VerdonckPVPascal Verdonck
- 26 July 2013
- journal article
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 19 (5) , 312-318
Abstract
Purpose: The purpose of this paper is to use rapid prototyping technology, in this case fused deposition modeling (FDM), to manufacture 2D and 3D particle image velocimetry (PIV) compatible patient‐specific airway models.Design/methodology/approach: This research has been performed through a case study where patient‐specific airway geometry was used to manufacture a PIV compatible model. The sacrificial kernel of the airways was printed in waterworks™ which is a support material used by Stratasys Maxum FDM devices. Transparent silicone with known refractive index was vacuum casted around the kernel and after curing out, the kernel was removed by washing out in sodium hydroxide.Findings: The resulting PIV model was tested in an experimental PIV setup to check the PIV compatibility. The results showed that the model performs quite well when the refractive index (RI) of the silicone and the fluid are matched.Research limitations/implications: Drawbacks such as the surface roughness, due to the size of the printing layers, and the yellowing of the silicone, due to the wash out of the kernel, need to be overcome.Originality/value: The paper presents the manufacturing process for making complex thick walled patient‐specific PIV models starting from a strong workable sacrificial kernel. This removable kernel is obtained by switching the building and the support materials of the FDM machine. In this way, the kernel was printed in support material while the building material was used to support the kernel during printing. The model was tested in a PIV setup and the results show that the airway model is suitable for performing particle image velocimetry.Keywords
This publication has 10 references indexed in Scilit:
- Experimental investigation of the transitional bronchial velocity distribution using stereo scanning PIVExperiments in Fluids, 2011
- Mitral Valve Leakage Quantification by Means of Experimental and Numerical Flow ModelingActa Mechanica Slovaca, 2010
- Patient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped MoldsJournal of Manufacturing Science and Engineering, 2008
- Validation of CFD predictions of flow in a 3D alveolated bend with experimental dataJournal of Biomechanics, 2008
- Time resolved analysis of steady and oscillating flow in the upper human airwaysExperiments in Fluids, 2007
- Dynamic flow in a realistic model of the upper human lung airwaysExperiments in Fluids, 2007
- Lung volume reduction surgery for diffuse emphysema2006
- Particle image velocimetry measurements in complex geometriesExperiments in Fluids, 2000
- Stereoscopic particle image velocimetry applied to liquid flowsExperiments in Fluids, 1993
- Particle-Imaging Techniques for Experimental Fluid MechanicsAnnual Review of Fluid Mechanics, 1991