Recommendations for Fluorescence Instrument Qualification: The New ASTM Standard Guide
Authors:
- 5 February 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (5) , 2129-2133
Abstract
Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide’s main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.Keywords
This publication has 25 references indexed in Scilit:
- Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array SpectrometersJournal of Research of the National Institute of Standards and Technology, 2009
- Standardization of Fluorescence Measurements: Criteria for the Choice of Suitable Standards and Approaches to Fit-for-Purpose Calibration ToolsAnnals of the New York Academy of Sciences, 2008
- Linking fluorescence measurements to radiometric unitsMetrologia, 2006
- Induced Gravity on Intersecting BranesJournal of High Energy Physics, 2004
- Fiber-Optic Quantum Counter Probe for Incident Excitation Energy Correction in Fluorescence MeasurementsApplied Spectroscopy, 2001
- Set of Secondary Emission Standards for Calibration of the Spectral Responsivity in Emission SpectroscopyApplied Spectroscopy, 1998
- Correction of Fluorescence SpectraApplied Spectroscopy, 1994
- Automated high precision variable aperture for spectrophotometer linearity testingApplied Optics, 1991
- Luminescence Standards for Macro- and Microspectrofluorometry1989
- Measurement of photoluminescence quantum yields. ReviewThe Journal of Physical Chemistry, 1971