Impact of Transcatheter Aortic Valve Durability on Life Expectancy in Low-Risk Patients With Severe Aortic Stenosis
- 28 July 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 142 (4) , 354-364
Abstract
Background: Recent clinical trial results showed that transcatheter aortic valve replacement (TAVR) is noninferior and may be superior to surgical aortic valve replacement (SAVR) for mortality, stroke, and rehospitalization. However, the impact of transcatheter valve durability remains uncertain. Methods: Discrete event simulation was used to model hypothetical scenarios of TAVR versus SAVR durability in which TAVR failure times were varied to determine the impact of TAVR valve durability on life expectancy in a cohort of low-risk patients similar to those in recent trials. Discrete event simulation modeling was used to estimate the tradeoff between a less invasive procedure with unknown valve durability (TAVR) and that of a more invasive procedure with known durability (SAVR). Standardized differences were calculated, and a difference >0.10 was considered clinically significant. In the base-case analysis, patients with structural valve deterioration requiring reoperation were assumed to undergo a valve-in-valve TAVR procedure. A sensitivity analysis was conducted to determine the impact of TAVR valve durability on life expectancy in younger age groups (40, 50, and 60 years). Results: Our cohort consisted of patients with aortic stenosis at low surgical risk with a mean age of 73.4±5.9 years. In the base-case scenario, the standardized difference in life expectancy was <0.10 between TAVR and SAVR until transcatheter valve prosthesis failure time was 70% shorter than that of surgical prostheses. At a transcatheter valve failure time <30% compared with surgical valves, SAVR was the preferred option. In younger patients, life expectancy was reduced when TAVR durability was 30%, 40%, and 50% shorter than that of surgical valves in 40-, 50-, and 60-year-old patients, respectively. Conclusions: According to our simulation models, the durability of TAVR valves must be 70% shorter than that of surgical valves to result in reduced life expectancy in patients with demographics similar to those of recent trials. However, in younger patients, this threshold for TAVR valve durability was substantially higher. These findings suggest that durability concerns should not influence the initial treatment decision concerning TAVR versus SAVR in older low-risk patients on the basis of current evidence supporting TAVR valve durability. However, in younger low-risk patients, valve durability must be weighed against other patient factors such as life expectancy.Keywords
This publication has 36 references indexed in Scilit:
- Modeling Using Discrete Event SimulationMedical Decision Making, 2012
- Reoperation of Left Heart Valve Bioprostheses According to Age at ImplantationCirculation, 2011
- Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk PatientsNew England Journal of Medicine, 2011
- Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity‐score matched samplesStatistics in Medicine, 2009
- The Society of Thoracic Surgeons 2008 Cardiac Surgery Risk Models: Part 1—Coronary Artery Bypass Grafting SurgeryThe Annals of Thoracic Surgery, 2009
- Using the Standardized Difference to Compare the Prevalence of a Binary Variable Between Two Groups in Observational ResearchCommunications in Statistics - Simulation and Computation, 2009
- Survival after valve replacement for aortic stenosis: Implications for decision makingThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Comparison of Carpentier-Edwards pericardial and supraannular bioprostheses in aortic valve replacementEuropean Journal of Cardio-Thoracic Surgery, 2006
- Prognosis After Aortic Valve Replacement With the Carpentier-Edwards Pericardial Valve: Use of MicrosimulationThe Annals of Thoracic Surgery, 2005
- Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulationHeart, 2004