Evaluating hydrologic performance of bioretention cells in shallow groundwater
- 12 October 2017
- journal article
- research article
- Published by Wiley in Hydrological Processes
- Vol. 31 (23) , 4122-4135
Abstract
Bioretention cells, which are generally effective in controlling surface runoff and recharging groundwater, have been widely adopted as low impact development practices. However, shallow groundwater has limited their implementation in some locations due to the potential problems of a reduction in surface runoff control, groundwater pollution, and continuous groundwater drainage through the underdrain. Many guidelines have established minimum requirements for the groundwater depth below bioretention cells, but they may not be optimized for certain environmental conditions and bioretention cell designs. This study made use of a variably saturated flow model to examine the hydrologic performance of a single bioretention cell in shallow groundwater with event‐based simulations, considering a wide range of initial groundwater depths, media and in situ soil types, surface runoff loads, and underdrain sizes. Performance indicators (e.g., runoff reduction, time for infiltrated water to reach the bioretention cell bottom and the groundwater table, and height and dissipation time of groundwater mound) were evaluated to examine the processes of runoff generation, the formation and dissipation of groundwater mounds, and the bioretention cell's performance in a shallow groundwater environment. The most influential factors were the initial groundwater depth, the hydraulic conductivity of the media soil, and the rainfall runoff load. With a deeper initial groundwater table, infiltrated water took longer to reach the bioretention cell bottom and groundwater table. Groundwater mounds, however, took longer to dissipate even though they were smaller. The groundwater quality can be better protected if relatively less‐permeable soil types (e.g., sandy loam) are used as the media, although it may compromise the performance in runoff quantity control. However, only very high surface runoff loads would cause concerns regarding a reduction in runoff quantity control and possible groundwater contamination due to the shallow groundwater. A distance of 1.5–3 m between the bioretention cell bottom and the groundwater table is generally sufficient. The results of this study could help to guide the planning and design of bioretention cells in areas of shallow groundwater.Keywords
Funding Information
- Seed Funding Programme for Basic Research of The University of Hong Kong (201611159011)
This publication has 39 references indexed in Scilit:
- Modelling infiltration enhancement in a tropical urban catchment for improved stormwater managementHydrological Processes, 2016
- Urban base flow with low impact developmentHydrological Processes, 2016
- Assessing cost-effectiveness of specific LID practice designs in response to large storm eventsJournal of Hydrology, 2016
- Impact of Variable Hydraulic Conductivity on Bioretention Cell Performance and Implications for Construction StandardsJournal of Hydraulic Engineering, 2013
- Calibration and validation of DRAINMOD to model bioretention hydrologyJournal of Hydrology, 2013
- Underdrain Configuration to Enhance Bioretention Exfiltration to Reduce Pollutant LoadsJournal of Environmental Engineering, 2011
- Impacts of Media Depth on Effluent Water Quality and Hydrologic Performance of Undersized Bioretention CellsJournal of Irrigation and Drainage Engineering, 2011
- Chemical fractionation of Cu and Zn in stormwater, roadway dust and stormwater pond sedimentsEnvironmental Pollution, 2010
- Storm-Water Infiltration and Focused Recharge Modeling with Finite-Volume Two-Dimensional Richards Equation: Application to an Experimental Rain GardenJournal of Hydraulic Engineering, 2009
- Developing joint probability distributions of soil water retention characteristicsWater Resources Research, 1988