A System for LogD Screening of 96-Well Plates Using a Water-Plug Aspiration/Injection Method Combined with High-Performance Liquid Chromatography−Mass Spectrometry
Authors:
- 2 October 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (21) , 8312-8315
Abstract
A system for screening of the octanol/water distribution coefficient (LogD) using automatic sampling of 96-well plates was developed. The high-speed assay for LogD (HSLogD) screening uses a water-plug aspiration/injection method combined with high-performance liquid chromatography−mass spectrometry (HPLC−MS). The method is useful for LogD analysis of highly hydrophobic compounds, where the concentration of the compound in the octanol phase is much higher than that in the water phase. In the case of LogD analyses, the conventional shake-flask method has been widely used, but it is difficult to increase the throughput of the shake-flask method because the lower water phase is carefully separated by manual separation without contamination of the upper octanol phase. We attempted to develop an automatic sampling method instead of manual separation to increase the throughput of the measurement. In initial attempts at automatic sampling, contamination of the octanol phase occurred when sampling of the water phase was made. This was because the octanol phase entered the sampling needle as it passed through to the lower water phase. This contamination was prevented by taking up a few microliters of water into the needle as a plug before sampling of the water phase (the water-plug aspiration/injection method). LogD values of some common drugs measured using the HSLogD agreed with reported LogD values (0 < LogD < 5).Keywords
This publication has 18 references indexed in Scilit:
- A Bioavailability ScoreJournal of Medicinal Chemistry, 2005
- High-Throughput Lipophilicity Measurement with Immobilized Artificial MembranesJournal of Medicinal Chemistry, 2005
- Separation methods for estimating octanol–water partition coefficientsJournal of Chromatography B, 2003
- Fast and direct method for measuring 1‐octanol–water partition coefficients exemplified for six local anestheticsJournal of Pharmaceutical Sciences, 2001
- ElogDoct: A Tool for Lipophilicity Determination in Drug Discovery. 2. Basic and Neutral CompoundsJournal of Medicinal Chemistry, 2001
- High Throughput Prediction of Oral Absorption: Improvement of the Composition of the Lipid Solution Used in Parallel Artificial Membrane Permeation AssaySLAS Discovery, 2001
- Rapid method for estimating the octanol–water partition coefficient (log Pow) by microemulsion electrokinetic chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 2000
- ElogPoct: A Tool for Lipophilicity Determination in Drug DiscoveryJournal of Medicinal Chemistry, 2000
- Determination of protonation macro- and microconstants and octanol/water partition coefficient of the antiinflammatory drug niflumic acidJournal of Pharmaceutical and Biomedical Analysis, 1994
- New chromatographic hydrophobicity index (ϕ0) based on the slope and the intercept of the log k′ versus organic phase concentration plotJournal of Chromatography A, 1993