Stiffness Requirements for Cross Bracing
- 1 December 1986
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 112 (12) , 2702-2707
Abstract
In the design of roof and wall double-diagonal cross bracing, the compression diagonal is usually ignored. The possibility of bracing provided to the compression diagonal by the loaded tension diagonal is examined. It is shown that the compression diagonal may be effectively braced at midspan through its connection to the tension diagonal, thereby increasing the total capacity of the double-diagonal cross bracing system.Keywords
This publication has 2 references indexed in Scilit:
- Design of Diagonal Roof Bracing Rods and TubesJournal of Structural Engineering, 1985