High versus low measurement frequency during 24-h ambulatory blood pressure monitoring - a randomized crossover study
Open Access
- 11 October 2023
- journal article
- research article
- Published by Springer Nature in Journal of Human Hypertension
- Vol. 38 (2) , 146-154
Abstract
Ambulatory blood pressure monitoring (ABPM) may be stressful and associated with discomfort, possibly influenced by the number of cuff inflations. We compared a low frequency (LF-ABPM) regimen with one cuff inflation per hour, with a high frequency (HF-ABPM) regimen performed according to current guidelines using three cuff-inflations per hour during daytime and two cuff-inflations during night time. In a crossover study, patients underwent ABPMs with both frequencies, in a randomized order, within an interval of a few days. Patients reported pain (visual analogue scale from 0 to 10) and sleep disturbances after each ABPM. The primary endpoint was the difference in mean 24 h systolic BP (SBP) between HF-ABPM and LF-ABPM. A total of 171 patients were randomized, and data from 131 (age 58 ± 14 years, 47% females, 24% normotensive, 53% mildly hypertensive, and 22% moderately-severely hypertensive) completing both ABPMs were included in the analysis. Mean SBP was 137.5 mmHg (95% CI, 134.8;140.2) for HF-ABPM and 138.2 mmHg (95%CI, 135.2;141.1) for LF-ABPM. The 95% limits of agreement were −15.3 mmHg and +14.0 mmHg. Mean 24 h SBP difference between HF-ABPM and LF-ABPM was −0.7 mmHg (95%CI, −2.0;0.6). Coefficients of variation were similar for LF-ABPM and HF-ABPM. Pain scores (median with interquartile range), for HF-ABPM and LF-ABPM were 1.5 (0.6;3.0) and 1.3 (0.6;2.9) during daytime, and 1.3 (0.4:3.4) and 0.9 (0.4;2.0) during nighttime (P < 0.05 for both differences). We conclude that LF-ABPM and HF-ABPM values are in good agreement without any clinically relevant differences in BP. Furthermore, LF-ABPM causes a relatively modest reduction in procedure-related pain.Keywords
This publication has 33 references indexed in Scilit:
- Reproducibility of ambulatory blood pressure in treated and untreated hypertensive patientsJournal Of Hypertension, 2010
- Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patientsBlood Pressure Monitoring, 2007
- 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?Blood Pressure Monitoring, 2001
- Reproducibility of ambulatory blood pressure monitoring in daily practiceJournal of Human Hypertension, 1999
- Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleepBMJ, 1994
- Factors affecting ambulatory blood pressure reproducibility. Results of the HARVEST Trial. Hypertension and Ambulatory Recording Venetia Study.Hypertension, 1994
- Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoringJournal Of Hypertension, 1992
- Reproducibility of non-invasive and intra-arterial blood pressure monitoring: implications for studies on antihypertensive treatmentJournal Of Hypertension, 1991
- Repeated measurements of ambulatory blood pressureJournal Of Hypertension, 1988
- Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.Hypertension, 1983