EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras
Authors:
Open Access
- 2 July 2019
- journal article
- research article
- Published by Springer Nature in European Journal of Hybrid Imaging
- Vol. 3 (1) , 1-27
Abstract
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.Keywords
This publication has 62 references indexed in Scilit:
- Rapid-acquisition myocardial perfusion scintigraphy (MPS) on a novel gamma camera using multipinhole collimation and miniaturized cadmium-zinc-telluride (CZT) detectors: prognostic value and diagnostic accuracy in a 'real-world' nuclear cardiology serviceEuropean Heart Journal - Cardiovascular Imaging, 2013
- Performance of a semiconductor SPECT system: comparison with a conventional Anger-type SPECT instrumentAnnals of Nuclear Medicine, 2012
- Cadmium-Zinc-Telluride Myocardial Perfusion Imaging in Obese PatientsJournal of Nuclear Medicine, 2012
- Prognostic value of automated vs visual analysis for adenosine stress myocardial perfusion SPECT in patients without prior coronary artery disease: A case-control studyJournal of Nuclear Cardiology, 2011
- Comparison Between Ultrafast and Standard Single-Photon Emission CT in Patients With Coronary Artery DiseaseCirculation: Cardiovascular Imaging, 2011
- Quantitative Upright–Supine High-Speed SPECT Myocardial Perfusion Imaging for Detection of Coronary Artery Disease: Correlation with Invasive Coronary AngiographyJournal of Nuclear Medicine, 2010
- Validation of CT Attenuation Correction for High-Speed Myocardial Perfusion Imaging Using a Novel Cadmium-Zinc-Telluride Detector TechniqueJournal of Nuclear Medicine, 2010
- Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac cameraEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector camerasJournal of Nuclear Cardiology, 2009
- EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2005